Familiarization to treadmill walking in unimpaired Parkinson's disease (PD) patients is assessed, across multiple treadmill walking sessions. Thirteen PD subjects were enrolled into the study (Eight were in a moderate stage of the disease, and 5 in an advanced stage). PD subjects attended a progressive program consisting of 12 sessions of 20 min. Walking speed, cadence, step length and coefficient of variation were assessed. ANOVA test were used to evaluate progression of disease and time influence over familiarization. PD Subjects baseline characteristics did not differ significantly between both groups and typical dependencies over progression of disease and velocity were found for cadence, step length and coefficient of variation. However, we showed that some PD subjects may require longer familiarization times and that familiarization is an adaptation process which involves parameters as velocity, cadence and gait stability. A better definition of familiarization to treadmill is needed since some parameters such as step length does not change significantly while others such as cadence, coefficient of variation and intraclass correlation coefficient does. Therefore familiarization to treadmill walking should remain on measures of velocity, cadence, reliability and variability. However, a bigger sample size is needed in order to improve the results of the present study.
Download full-text PDF |
Source |
---|
BMJ Open
January 2025
College of Medicine and Dentistry, James Cook University, Queensland Research Centre for Peripheral Vascular Disease, Townsville, Queensland, Australia.
Introduction: Patients with peripheral artery disease (PAD) can experience intermittent claudication, which limits walking capacity and the ability to undertake daily activities. While exercise therapy is an established way to improve walking capacity in people with PAD, it is not feasible in all patients. Neuromuscular electrical stimulation (NMES) provides a way to passively induce repeated muscle contractions and has been widely used as a therapy for chronic conditions that limit functional capacity.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Electrical and Information Engineering, Kiel University, 24143 Kiel, Germany.
Clinical motion analysis plays an important role in the diagnosis and treatment of mobility-limiting diseases. Within this assessment, relative (point-to-point) tracking of extremities could benefit from increased accuracy. Given the limitations of current wearable sensor technology, supplementary spatial data such as distance estimates could provide added value.
View Article and Find Full Text PDFSensors (Basel)
January 2025
College of Sport and Health Science, Ritsumeikan University, Kusatsu 525-8577, Shiga, Japan.
This study aimed to assess the intraday reliability of markerless gait analysis using an RGB-D camera versus a traditional three-dimensional motion analysis (3DMA) system with and without a simulated walking assistant. Gait assessments were conducted on 20 healthy adults walking on a treadmill with a focus on spatiotemporal parameters gathered using the RGB-D camera and 3DMA system. The intraday reliability of the RGB-D camera was evaluated using intraclass correlation coefficients (ICC 1, 1), while its consistency with the 3DMA system was determined using ICC (2, 1).
View Article and Find Full Text PDFJ Biomech
January 2025
UNC-NC State Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, 1407, Engineering Building III, 1840 Entrepreneur Drive, Raleigh, NC 27695, USA. Electronic address:
Continuous relative phase (CRP) quantifies coordination for cyclic motions as the difference in the phase portrait locations between its constituent coordinates and has been widely used in populations with neuromuscular impairments. Continuous analyses, like statistical parameter mapping (SPM), provide greater resolution than traditional techniques that first compress CRP across a section of the cycle to a single point, like mean average relative phase (MARP). However, both analyses neglect the effect of intermediate event timing (e.
View Article and Find Full Text PDFPLoS One
January 2025
CFD Research Corporation, Huntsville, AL, United States of America.
Purpose: To assess physiological metrics during the use of a commercially available bilateral active ankle exoskeleton during a challenging military-relevant task and if use of the exoskeleton during this task influences: metabolic load, physiological measures or rate of perceived exertion.
Methods: Nine healthy volunteers (5M, 4F) completed this randomized cross-over design trial, with a baseline visit and two randomized test sessions (with/without the exoskeleton). Variables included impact on time to exhaustion during walking on a treadmill at varying speeds and gradients (0-15%) at 26.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!