A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An impedance immunosensor based on low-cost microelectrodes and specific monoclonal antibodies for rapid detection of avian influenza virus H5N1 in chicken swabs. | LitMetric

Early screening of suspected cases is the key to control the spread of avian influenza (AI) H5N1. In our previous studies, an impedance biosensor with an interdigitated array microelectrode based biochip was developed and validated with pure AI H5 virus, but had limitations in cost and reliability of the biochip, specificity of the antibody against Asian in-field H5N1 virus and detection of H5N1 virus in real samples. The purpose of this study is to develop a low-cost impedance immunosensor for rapid detection of Asian in-field AI H5N1 virus in chicken swabs within 1h and validate it with the H5N1 virus. Specific monoclonal antibodies against AI H5N1 virus were developed by fusion of mouse myeloma cells with spleen cells isolated from an H5N1-virus-immunized mouse. Dot-ELISA analysis demonstrated that the developed antibodies had good affinity and specificity with the H5N1 virus. The microelectrodes were redesigned with compact size, fabricated using an improved wet-etching micro-fabrication process with a higher qualified production rate of 70-80%, and modified with the antibodies by the Protein A method. Equivalent circuit analysis indicated that electron transfer resistor was effective with the increase in impedance after capturing of the H5N1 viruses. Linear relationship between impedance change and logarithmic value of H5N1 virus at the concentrations from 2(-1) to 2(4) HAU/50 μl was found and the lower limit of detection was 2(-1) HAU/50 μl. No obvious interferences from non-target viruses such as H6N2, H9N2, Newcastle disease virus, and infectious bronchitis virus were found. Chicken swab tests showed that the impedance immunosensor had a comparable accuracy with real-time RT-PCR compared to viral isolation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2014.09.037DOI Listing

Publication Analysis

Top Keywords

h5n1 virus
28
impedance immunosensor
12
virus
11
h5n1
10
specific monoclonal
8
monoclonal antibodies
8
rapid detection
8
avian influenza
8
chicken swabs
8
asian in-field
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!