In this work, a method is presented that can calculate the lower bound of the timing resolution for large scintillation crystals with non-negligible photon transport. Hereby, the timing resolution bound can directly be calculated from Monte Carlo generated arrival times of the scintillation photons. This method extends timing resolution bound calculations based on analytical equations, as crystal geometries can be evaluated that do not have closed form solutions of arrival time distributions. The timing resolution bounds are calculated for an exemplary 3 mm × 3 mm × 20 mm LYSO crystal geometry, with scintillation centers exponentially spread along the crystal length as well as with scintillation centers at fixed distances from the photosensor. Pulse shape simulations further show that analog photosensors intrinsically operate near the timing resolution bound, which can be attributed to the finite single photoelectron pulse rise time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4216231PMC
http://dx.doi.org/10.1088/0031-9155/59/20/6215DOI Listing

Publication Analysis

Top Keywords

timing resolution
24
resolution bound
16
photon transport
8
scintillation centers
8
resolution
6
bound
5
timing
5
lower timing
4
bound scintillators
4
scintillators non-negligible
4

Similar Publications

Diagnostic role of sonography in early detection and surgical intervention of an epidural abscess: A case report.

Australas J Ultrasound Med

November 2024

Argentinian Critical Care Ultrasonography Association (ASARUC) Buenos Aires C1424FSD Argentina.

Introduction: Intracranial epidural abscesses require swift diagnosis and treatment. While magnetic resonance imaging (MRI) is preferred for its detailed visualisation, it is costly and time-consuming. Transcranial sonography offers a rapid, portable and cost-effective alternative for assessing brain lesions.

View Article and Find Full Text PDF

[Clinical analysis of 8 cases of spontaneous cerebrospinal fluid rhinorrhea with aspiration pneumonia].

Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi

December 2024

Department of Otorhinolaryngology Head and Neck Surgery, Yuhuangding Hospital of Qingdao University, Yantai264000, China Shandong Provincial Clinical Research Center for Otorhinolaryngologic Diseases, Yantai264000, China Yantai Key Laboratory of Otorhinolaryngologic Diseases, Yantai264000, China.

To investigate the clinical characteristics, treatment, and efficacy of spontaneous cerebrospinal fluid rhinorrhea (CFR) combined with aspiration pneumonia. In this case series study, a total of 8 patients diagnosed with spontaneous CFR combined with aspiration pneumonia were admitted to the Department of Otorhinolaryngology Head and Neck Surgery at Yuhuangding Hospital Affiliated with Qingdao University from March 2020 to March 2022. There were 3 males and 5 females, with ages ranging from 45 to 57 years.

View Article and Find Full Text PDF

Background: Metabolic bariatric surgery is the most effective therapy for severe obesity, which affects the health of millions, most of whom are women of child-bearing age. Roux-en-Y gastric bypass (RYGB) and sleeve gastrectomy (SG) are the most common bariatric procedures and are associated with durable weight loss and comorbidity resolution. Although obstetric outcomes broadly improve, the safety profile comparing the impact of RYGB and SG on obstetric outcomes is underexplored.

View Article and Find Full Text PDF

Burkholderia pseudomallei, a soil-borne bacterium that causes melioidosis, endemic in South and Southeast Asia and northern Australia, is now emerging in new regions. Since the 1990s, cases have been reported in French overseas departments, including Martinique and Guadeloupe in the Caribbean, and Reunion Island and Mayotte in the Indian Ocean, suggesting a local presence of the bacterium. Our phylogenetic analysis of 111 B.

View Article and Find Full Text PDF

Design and commissioning of the PRIOR-II "proton microscope for FAIR".

Rev Sci Instrum

December 2024

Plasmaphysics Department, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstrasse 1, 64291 Darmstadt, Germany.

A new high energy proton radiography facility PRIOR-II (Proton Microscope for FAIR) has been designed, constructed, and successfully commissioned at the GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany) pushing the technical boundaries of charged particle radiography with normal conducting magnets to the limits. The setup is foreseen to become a new and powerful user facility for carrying out fundamental science experiments in the fields of plasma and shock wave physics, material science, and medical physics. It will help address several unsolved scientific challenges, which require high-speed and precise non-invasive diagnostic methods capable of probing matter with up to 100 g/cm2 areal density.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!