The clinical applications of mean platelet volume (MPV) have recently broadened far beyond the differential diagnosis of platelet (PLT) disorders to embrace diagnosis and prognostication of a variety of thrombotic conditions. As the potential usefulness of this simple and inexpensive parameter may be challenged by instrument heterogeneity, we investigated the degree of analytical quality and interinstrument comparability. One hundred consecutive inpatient samples were simultaneously assessed on Abbott Sapphire, Mindray BC6800, Siemens Advia 2120, and Sysmex XE5000. The within-run imprecision of the four hematological analyzers was also assessed according to the Clinical and Laboratory Standards Institute document EP5-A2. The imprecision of PLT count ranged between 1.4 and 4.3%, and hence was always within the desirable quality specifications. The within-run imprecision of MPV ranged between 1.1 and 3.8%, and hence was also within the desirable quality specifications. The optical and impedance measurements displayed excellent correlations. Overall, the PLT count exhibited a modest instrumental variation, with bias always within the desirable quality specifications. A large bias was instead recorded for MPV, with between-instrument variations exceeding the desirable quality specifications in five out of six interinstrumental comparisons. No significant correlation was also observed between PLT count and MPV with any of the instruments tested. These results attest that although there is an optimal degree of analytical quality and comparability for PLT counting among different hemocytometers, the harmonization of MPV is poor, thus making the adoption of universal cutoffs virtually impossible.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBC.0000000000000220DOI Listing

Publication Analysis

Top Keywords

desirable quality
16
quality specifications
16
plt count
12
platelet volume
8
hematological analyzers
8
degree analytical
8
analytical quality
8
within-run imprecision
8
quality
6
mpv
5

Similar Publications

Objectives: We evaluated the performance of a novel flow cell morphology analyzer AUTION EYE AI-4510 for counting particles in urine.

Methods: Analytical performance was assessed according to the EFLM European Urinalysis Guideline 2023. Trueness was compared by analyzing 1.

View Article and Find Full Text PDF

Comparability of the LDH measurement and analysis based on external quality assessment.

Clin Chim Acta

January 2025

Department of Clinical Laboratory, Beijing Chaoyang Hospital, The Third Clinical Medical College of Capital Medical University, Beijing Center for Clinical Laboratories, No. 8 Gongti South Road, Chaoyang District, Beijing 100020, PR China. Electronic address:

Background: Lactate dehydrogenase (LDH) is a critical enzyme widely used in clinical diagnostics. However, variations in measurement systems can lead to inconsistent results, potentially impacting clinical decision-making. This study aimed to evaluate the comparability of lactate dehydrogenase measurements by comparing routine methods with the IFCC reference method, and to analyze the standardization status of LDH testing through external quality assessment (EQA).

View Article and Find Full Text PDF

Introduction: There is a general impression that patient-based quality control (PBQC) requires a high volume of laboratory results to detect errors effectively. However, internal quality control (IQC) performed infrequently may be associated with increased risk of missed error (i.e.

View Article and Find Full Text PDF

Variations in the proportions of the two major soybean [Glycine max (L.) Merr.] seed globulins, glycinin (11S) and β-conglycinin (7S), significantly affect the nutritional and functional properties of soy-based products, but comprehensive methods for the identification and quantification of individual subunits of these proteins are currently lacking.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!