Mapping camphorquinone consumption, conversion and mechanical properties in methacrylates with systematically varied CQ/amine compositions.

Dent Mater

Oregon Health and Science University, School of Dentistry, Biomaterials and Biomechanics, Portland, OR, USA. Electronic address:

Published: November 2014

Objectives: To evaluate conversion, bulk mechanical properties and camphorquinone (CQ) consumption in methacrylate resins, comprising a range of overall initiator concentrations and CQ/amine ratios.

Methods: BisGMA (Bisphenol-A glycidyl dimethacrylate), TEGDMA (triethyleneglycol dimethacrylate) and UDMA (urethane dimethacrylate) were mixed at a 1:1:1 molar ratio. CQ was used as the visible light photosensitizer, in combination with EDMAB (Ethyl p-dimethylamino benzoate), at 3:1, 2:1, 1:1, 1:2 and 1:3 weight ratios, at 0.5, 1.0, 1.5, 2.0 and 3.0 wt% overall initiator concentration. Butylhydroxytoluene was added at 0.05 wt% as an inhibitor. Unfilled resins were photoactivated with a dental light source (VIP Jr, Bisco) for 60 s at 600 mW/cm(2). Flexural strength/modulus were assessed in 2×1×10 mm bars, tested in three-point bending. Degree of conversion was assessed at the bottom of the same specimens using FT-RAMAN. CQ consumption was measured using a UV-vis spectrometer. Data were analyzed with two-way ANOVA/Tukey test (α=5%).

Results: Lower conversion and inferior mechanical properties were observed with lower overall initiator concentrations and higher amine/CQ ratios. The lowest overall initiator concentration (0.5%) presented the statistically lowest conversion/properties results, except for the 1:3 amine/CQ ratio. For overall concentrations equal or greater to 1.5%, the amine/CQ ratio did not influence conversion or mechanical properties. CQ consumption was less efficient for the highest overall initiator concentrations and lower amine/CQ ratios.

Clinical Relevance: Above 1.5 wt% overall initiator concentration, the conversion and general mechanical properties were independent of the initiator concentration. Therefore, there seems to be no benefit to increasing the initiator concentration above that level. At higher camphorquinone concentrations, light transmission and photosensitizer consumption becomes impaired, which could lead to decreased depth of cure and yellowing of the restoration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2014.08.379DOI Listing

Publication Analysis

Top Keywords

mechanical properties
20
initiator concentration
20
initiator concentrations
12
camphorquinone consumption
8
conversion mechanical
8
initiator
8
wt% initiator
8
amine/cq ratio
8
conversion
6
consumption
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!