Background And Aim: Much previous research on orthotic walkers has focussed on their ability to offload structures in the foot and ankle; however, little is known about their effects on lower limb mechanics. This study aimed to determine effects of two orthotic walkers on the biomechanics of the knee and hip joints compared to standardised footwear.
Technique: A total of 10 healthy participants walked under three conditions: Walker A (Össur, Iceland), Walker B (DJO Global, USA) and standardised footwear (Hotter, UK). Kinematic and kinetic data were collected using a Qualisys motion analysis system (Qualisys Medical AB, Sweden) and force plates (AMTI, Boston, MA, USA). Significant differences were seen in hip kinematics and knee moments between walkers and standardised footwear and in knee kinematics between Walker A and standardised footwear.
Discussion: Both walkers show significant kinematic and kinetic differences compared with standardised footwear; however, Walker A appeared to produce greater deviation, including potentially damaging greater hyperextension moments at the knee.
Clinical Relevance: Further research is needed into the effects of orthotic walkers on knee and hip joint mechanics, which should help to inform future designs of walker, with greater focus on obtaining a more normal gait pattern.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0309364614546525 | DOI Listing |
J Foot Ankle Res
March 2025
The University of South Australia, Allied Health & Human Performance Unit, Adelaide, SA, Australia.
Background: This study investigated the effect of various offloading devices commonly used for the management of diabetic foot ulcerations on peak plantar pressure and pressure-time integral of the contralateral limb.
Methods: A quantitative, randomised and within-subject repeated measures study was conducted in an outpatient gait laboratory. Outpatients with unilateral diabetic foot ulcers and adequate perfusion to the lower limb without an intrinsic limb-length discrepancy who were able to walk were recruited for the study.
Clin Orthop Surg
December 2024
Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea.
Background: The choice of an appropriate type of orthosis depends on the patient's specific condition and needs. Different types of orthoses can affect plantar pressure distribution during certain gait patterns. Toe and heel gaits are common patterns of gait assigned for optimal recovery in patients with foot or ankle injuries.
View Article and Find Full Text PDFProsthet Orthot Int
November 2024
St. John's Rehab Research Program, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
Background: The clinical landscape of limb loss rehabilitation across Canada is poorly delineated, lacks standard rehabilitation guidelines, and is without a shared clinical database.
Objective: To address these gaps, the objective of the present study was to undertake an environmental scan of the rehabilitation centers across Canada that provide inpatient and/or outpatient services to the limb loss community.
Study Design: An environmental scan was conducted to describe the rehabilitation service structure, program services, and outcome measures of sites across Canada.
J Biomech
November 2024
Carnegie School of Sport, Leeds Beckett University, Leeds, United Kingdom. Electronic address:
Research investigating ankle function during walking in a controlled ankle motion (CAM) boot has either placed markers on the outside of the boot or made major alterations to the structure of the CAM boot to uncover key landmarks. The aim of this study was to quantify joint kinematics and kinetics using "in-boot" skin markers whilst making only minimal structural alterations. Seventeen healthy participants walked at their preferred walking speed in two conditions: (1) in standard athletic trainers (ASICS patriot 8, ASICS Oceania Pty Ltd, USA), and (2) using a hard-cased CAM boot (Rebound® Air Walker, Össur, Iceland) fitted on the right foot.
View Article and Find Full Text PDFJ Foot Ankle Res
September 2024
Multidisciplinary Diabetes Foot Unit, Fiona Stanley Hospital, Perth, Western Australia, Australia.
Background: Pressure offloading is a critical component of plantar foot ulcer management, including diabetes-related foot ulcers (DFU). Conventional offloading options such as total contact casting and removable knee-high walkers may be unsuitable or unsuccessful in patients with morbid obesity, intermittent lower limb oedema, high exudative wounds or poor mobility. A mouldable fibreglass backslab device (BSD) may be a practical alternative to be considered in these situations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!