Ultrasonic coded transmitters (UCTs) are high-frequency acoustic tags that are often used to conduct survivorship studies of vulnerable fish species. Recent observations of differential mortality in tag control studies suggest that fish instrumented with UCTs may be selectively targeted by marine mammal predators, thereby skewing valuable survivorship data. In order to better understand the ability of pinnipeds to detect UCT outputs, behavioral high-frequency hearing thresholds were obtained from a trained harbor seal (Phoca vitulina) and a trained California sea lion (Zalophus californianus). Thresholds were measured for extended (500 ms) and brief (10 ms) 69 kHz narrowband stimuli, as well as for a stimulus recorded directly from a Vemco V16-3H UCT, which consisted of eight 10 ms, 69 kHz pure-tone pulses. Detection thresholds for the harbor seal were as expected based on existing audiometric data for this species, while the California sea lion was much more sensitive than predicted. Given measured detection thresholds of 113 dB re 1 μPa and 124 dB re 1 μPa, respectively, both species are likely able to detect acoustic outputs of the Vemco V16-3H under water from distances exceeding 200 m in typical natural conditions, suggesting that these species are capable of using UCTs to detect free-ranging fish.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/1.4868371 | DOI Listing |
Micromachines (Basel)
December 2024
School of Engineering, Liverpool John Moores University, Liverpool L3 3AF, UK.
Coaxial rotor helicopters have many advantages and have a wide range of civilian and military applications; however, there is a risk of blade collision between the upper and lower rotor blades, and the challenge still exists in balancing rotor parameters and flight control. In this paper, a blade tip distance measurement method based on coded ultrasonic ranging and phase triggering is proposed to tackle this measurement environment and expand the application of ultrasonic ranging in high-speed dynamic measurement. The time of flight () of coded ultrasonic ranging is calculated by the amplitude threshold improvement method and cross-correlation method, and the sound velocity is compensated by a proposed multi-factor compensation method.
View Article and Find Full Text PDFJ Clin Neurosci
January 2025
Department of Ultrasonic Medicine, Fudan University Affiliated Huashan Hospital, No 12, Middle Wulumuqi Road, Shanghai 200040, China. Electronic address:
Objective: This prospective observational study aimed to assess the effectiveness of B-mode ultrasound, color-coded Doppler, and shear-wave elastography in predicting intracranial pressure (ICP) and their capability to evaluate the efficacy of ICP lowering therapy.
Materials And Methods: Forty-eight neuro-critical care patients were enrolled and categorized into 2 groups based on ICP measurements obtained through external ventricular drainage: the intracranial hypertension (IH) and normal ICP groups. The optic nerve (ON) sheath diameter (ONSD), end diastolic velocity, peak systolic velocity, resistance index of the central retinal artery (CRA), and Young's modulus (YM) of the ON were recorded after external ventricular drainage placement and following ICP lowering treatment in the IH group.
Ultrasonics
January 2025
Medical Ultrasound Department for the Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China. Electronic address:
Shear Wave Elastography (SWE) is an imaging technique that detects shear waves generated by tissue excited by Acoustic Radiation Force (ARF), and characterizes the mechanical properties of soft tissue by analyzing the propagation velocity of shear wave. ARF induces a change in energy density through the nonlinear propagation of ultrasound waves, which drives the tissue to generate shear waves. However, the amplitude of shear waves generated by ARF is weak, and the shear waves are strongly attenuated in vivo.
View Article and Find Full Text PDFJ Neurophysiol
December 2024
Department of Neuroscience, Brown University, Providence, Rhode Island, United States.
Echolocating big brown bats () detect changes in ultrasonic echo delay with an acuity as sharp as 1 µs or less. How this perceptual feat is accomplished in the nervous system remains unresolved. Here, we examined the precision of latency registration (latency jitter) in neural population responses as a possible mechanism underlying the bat's hyperacuity.
View Article and Find Full Text PDFUltrasonics
March 2025
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, T6G 1H9, AB, Canada.
3D synthetic aperture (SA) imaging of volumes can be obtained using sparse 2D ultrasound arrays. However, even with just 256 elements, the volumetric imaging rate can be relatively slow due to having to transmit on each element in succession. Hadamard Aperiodic Interval (HAPI) codes can be used to image the full SA dataset in one extended transmit to speed up the synthetic aperture imaging, but their long nature produces large deadzones if the same elements are used as both transmitters and receivers.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!