Circulating soluble receptor for advanced glycation end product identifies patients with bicuspid aortic valve and associated aortopathies.

Arterioscler Thromb Vasc Biol

From the Department of Surgery, Thoracic Aortic Program, Perelman School of Medicine at University of Pennsylvania, Philadelphia (E.B., J.E.B., J.B.G., P.P., E.K.L., N.D.D., J.H.G., R.C.G., G.F.); and Department of Surgery, Valley Hospital, Columbia University, Ridgewood, NJ (R.E.S.).

Published: October 2014

Objective: A total of 30% to 50% of patients with bicuspid aortic valve (BAV) require surgery for aortic valve replacement (AVR), ascending aortic replacement (AA), or both. To prevent adverse aortic events, they are risk stratified using imperfect criteria based on imaging modalities. As a result, a significant number of dissections occur outside of the parameters suggested by the guidelines. Advanced glycation end products (AGEs) are associated with valve and vascular remodeling and trigger the release of a soluble receptor (soluble receptor for advanced glycation end product [sRAGE]). This study aims to characterize sRAGE as a diagnostic and risk-stratification tool for patients with BAV referred for surgery.

Approach And Results: sRAGE was measured in 135 patients (BAV, n=74; tricuspid aortic valve, n=61) meeting inclusion criteria from 338 enrolled patients undergoing AVR and AA. Univariate and multivariate analyses were performed. sRAGE level was significantly associated with the presence of BAV, independent of age, sex, and common risk factors for vascular disease (P<0.001). Within the BAV cohort, patients referred for AA and AVR had higher sRAGE values than patients undergoing AVR only (P=0.002). Patients with BAV <60 years of age, presenting with both valve and aortic diseases (fast progressors), had higher sRAGE than older patients who only needed AVR (slow progressors). Histological analysis showed that sRAGE correlates with dysfunctional aortic microstructure and does not correlate with aortic diameter (R(2)=0.007; P=0.51) or diameter/body surface area (R(2)=0.011; P=0.42).

Conclusions: These results show that elevated level of circulating sRAGE is associated with the presence of BAV and associated aortopathies, independent of aortic diameter.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685423PMC
http://dx.doi.org/10.1161/ATVBAHA.114.303784DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
soluble receptor
12
advanced glycation
12
receptor advanced
8
glycation product
8
patients bicuspid
8
bicuspid aortic
8
patients bav
8
aortic
6
patients
5

Similar Publications

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

The VACTERL (vertebral defects, anal atresia, cardiac defects, tracheoesophageal fistula, renal anomalies, and limb abnormalities) association represents an enigmatic syndrome requiring further study. This report describes a full-term neonate born to a multiparous woman who was found, upon further examination, to have multiple congenital abnormalities, including a bicuspid aortic valve, patent foramen ovale, tracheoesophageal fistula (TEF), asymmetric crying facies, microphallus, and a single inguinal testis. The discussion explores environmental and genetic factors that may contribute to this association, as well as similar conditions, such as CHARGE (coloboma, heart defects, choanal atresia, growth retardation, genital abnormalities, and ear abnormalities) syndrome.

View Article and Find Full Text PDF

The Y incision and roof technique for aortic valve replacement enable implantation of a large prosthetic valve and extensive enlargement of the sinotubular junction. Surgeons have been reluctant to adopt a minimally invasive approach for this procedure because of its complexity and risk. The Stonehenge technique was designed to achieve an ideal surgical view of the aortic root through a small right thoracotomy.

View Article and Find Full Text PDF

Valve-sparing aortic root replacements have acceptable reintervention rates in patients with failed pulmonary autografts after a Ross procedure. In our 50-year-old patient with post-Ross valve-sparing aortic root replacement, we report preoperative and postoperative 4-dimensional flow magnetic resonance imaging capturing changes in peak systolic velocity, 3-dimensional systolic flow profiles, and aortic wall shear stress that may predict a decreased risk of aortic dilation, a common complication in repeated Ross procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!