Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Indacaterol is a novel once-a-day inhaled ultra-long-acting β2-agonist. Quantitative bioanalysis supports pharmacokinetic and clinical research. The aim of the current work was to validate an in-house developed high performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) analytical method for indacaterol determination in human urine samples.
Methods: A liquid-liquid extraction method has been developed to extract indacaterol from human urine samples using ethyl acetate. Indacaterol dry extract was reconstituted with 200 μL of the mobile phase (acidified water:methanol (30:70, v/v)) of which 5 μL was needed for the HPLC-MS/MS analysis. Indacaterol was eluted on a reversed C18 stationary phase with an isocratic mobile phase at a flow of 1 mL/min. Formoterol was the internal standard (IS). The MS/MS detection was employed with a turbo-ion spray ionization in the positive ion mode. A consensus of the international Guidelines for Bioanalytical Method Validation was followed.
Results: Indacaterol was detected at a mass to charge ratio (m/z) of 393.3 and its MS/MS daughter at 173.2. The retention times of indacaterol and IS were 1.60 and 1.20 min, respectively. Validated calibration curves were linear over a range of 0.075-100 ng/mL with correlation coefficients (r)≥0.990. The curves' regression weighting factor was 1/x. Method specificity was established in six different human urine batches. No matrix interference was observed. The intra- and inter-batch precision and accuracy within±20% (at lower limit) and±15% (other quality control (QC) levels) were confirmed. The indacaterol mean recovery (precision) percentages at Low, Mid, and High QC levels were 93.5 (3.84), 89.8 (2.15), and 92.2 (2.17), respectively. Short-term, long-term, freeze-thaw, and auto-sampler stability results were accepted.
Conclusions: A specific, accurate and precise HPLC-MS/MS method has been validated for indacaterol quantification in human urine. This simple method is reproducible and robust to support future, indacaterol-related pharmacokinetic, bioequivalence and clinical studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/jamp.2014.1153 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!