Phospholipid removal combined with a semi-automated 96-well SPE application for determination of budesonide in human plasma with LC-MS/MS.

J Chromatogr B Analyt Technol Biomed Life Sci

Department of Laboratory Medicine, Division of Clinical Pharmacology, Karolinska Institute and University Hospital, Stockholm, Sweden.

Published: November 2014

A semi-automated method for quantification of budesonide in human plasma was developed, validated, and applied for high-volume analysis of samples in connection with a pharmacokinetic study. Protein and phospholipid removal was performed using an Ostro 96-well filter plate and subsequently combined with C18 solid-phase extraction on a Hamilton Microlab STARlet automation robot. The final extracts were evaporated to dryness and redissolved in 20% acetonitrile/water. The procedure used budesonide-d8 as internal standard and gave a 3.5-fold concentration of plasma to extract. The final extracts (5 μL injected) were analyzed with selected reaction monitoring liquid chromatography-tandem mass spectrometry (LC-MS/MS) using electrospray ionization in positive mode. The chromatography system used a 100 mm ACQUITY BEH UPLC column and a gradient system consisting of aqueous 0.1% formic acid and acetonitrile as organic modifier. Phospholipid removal was found to be needed during method development in order to reduce ion suppression effects from matrix and to increase method sensitivity. The measuring range was 50-5000 pg/mL with and LOD 24 pg/mL. Calibration response showed good linearity (correlation coefficients<0.99) over the measuring range. The absolute recovery over the sample preparation procedure was estimated to 67%. Total imprecision was <9% at three levels and accuracy was between 98.9 and 103%. The method was successfully applied for analysis of 864 study samples in a short time. The quality control samples at concentration levels 200 and 2000 pg/mL gave a total imprecision of 7.4% and 4.2%, respectively, (n=95).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2014.08.035DOI Listing

Publication Analysis

Top Keywords

phospholipid removal
12
budesonide human
8
human plasma
8
final extracts
8
removal combined
4
combined semi-automated
4
semi-automated 96-well
4
96-well spe
4
spe application
4
application determination
4

Similar Publications

Bacterial and fungal diversity and species interactions inversely affect ecosystem functions under drought in a semi-arid grassland.

Microbiol Res

January 2025

Key Laboratory of Vegetation Ecology, Ministry of Education, Institute of Grassland Science, Northeast Normal University, Changchun, China; State Environmental Protection Key Laboratory of Wetland Ecology and Vegetation Restoration, School of Environment, Northeast Normal University, Changchun, China. Electronic address:

Extreme climatic events, such as drought, can significantly alter belowground microbial diversity and species interactions, leading to unknown consequences for ecosystem functioning. Here, we simulated a drought gradient by removing 30 %, 50 %, and 70 % of precipitation in a semi-arid grassland over five years. We assessed the effects of drought on bacterial and fungal diversity, as well as on their species interactions.

View Article and Find Full Text PDF

Cannabidiol (CBD) and Δ-tetrahydrocannabinol (THC), the main components of Cannabis sativa plants, can interact with specific cell receptors known as cannabinoid receptors (CBs). The endogenous compounds anandamide (AEA) and 2-arachidonoylglycerol (2-AG) are CB agonists, and, alongside enzymes, they constitute the endocannabinoid system (ECS) and take part in neuromodulation. Several LC-MS/MS methods have been developed to quantify these compounds in biological matrixes, but a fast and simple method that can determine these analytes in plasma samples simultaneously is not available.

View Article and Find Full Text PDF

Mechanism of nonhydrated phospholipid removal in soybean oil using aminopolycarboxylic acid ligands.

Food Chem

January 2025

Laboratory of Nutrition and Functional Food, College of Food Science and Engineering, Jilin University, Changchun 130062, PR China. Electronic address:

Herein, nonhydrated phospholipids (NHPs) were removed from soybean oil using three silica adsorbents modified using aminopolycarboxylic acid ligands. The removal rate of NHPs was 62.98 %.

View Article and Find Full Text PDF

Contribution of individual phospholipase A enzymes to the cleavage of oxidized phospholipids in human blood plasma.

J Lipid Res

January 2025

Institute of Pharmaceutical Sciences, Department of Pharmaceutical Chemistry, University of Graz, Graz, Austria; Field of Excellence BioHealth - University of Graz, Graz, Austria. Electronic address:

Phospholipids containing oxidized esterified PUFA residues (OxPLs) are increasingly recognized for multiple biological activities and causative involvement in disease pathogenesis. Pharmacokinetics of these compounds in blood plasma is essentially not studied. Human plasma contains both genuine phospholipases A (PAF-AH (also called Lp-PLA) and sPLA) and multifunctional enzymes capable of removing sn-2 residues in native and oxidized PLs (LCAT, PRDX6).

View Article and Find Full Text PDF

Lipophilicity Modulation of Fluorescent Probes for Imaging of Cellular Microvesicle Dynamics.

J Am Chem Soc

January 2025

School of Chemistry and Chemical Engineering, Institute of Physical Science and Information Technology, Information Materials and Intelligent Sensing Laboratory of Anhui Province, Key Laboratory of Structure and Functional Regulation of Hybrid Materials of Ministry of Education, Anhui University, Hefei, Anhui 230601, China.

Real-time monitoring of dynamic microvesicles (MVs), vesicles associated with living cells, is of great significance in deeply understanding their origin, transport, and function. However, specific labeling MVs poses a challenge due to the lack of unique biomarkers that differentiate them from other cellular compartments. Here, we present a strategy to selectively label MVs by evaluating a series of lipid layer-sensitive cationic indolium-coumarin fluorescent probes (designated as IC-C, with ranging from 1 to 18) that feature varying aliphatic side chains (CH).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!