Background: The success of dental implants depends on the manner in which stresses are transferred to the surrounding bone. An important consideration is to design an implant with a geometry that will minimize the peak bone stresses caused by standard loading. The aim of this study was to assess the influence of implant thread geometry on biomechanical load transfer and to compare the difference between two different thread designs.
Materials And Methods: A three-dimensional finite element model of D2 bone representing mandibular premolar region was constructed. Two implants of differing thread geometries, 13-mm length, and 4-mm diameter along with superstructures were simulated. One design featured fourfold microthread of 0.4-mm pitch, 0.25-mm depth in the crestal one-third; 0.8-mm pitch, 0.5-mm depth in the apical two-third. The other design had a single-pitch microthread of 0.8-mm pitch, 0.25-mm depth in the crestal one-third; 0.8-mm pitch, 0.5-mm depth in the apical two-third. A static axial load of 100-N was applied to the occlusal surface of the prosthesis. ANSYS CLASSIC 9.0 (PA,USA)software was used for stress analysis as von Mises stresses.
Results: A comparison of von Mises stresses between two thread designs revealed that fourfold microthread allows better stress distribution within the implant body by 43.85%, abutment by 15.68%, its superstructure by 39.70% and 36.30% within cancellous bone as compared to single-pitch microthread. The effective stress transfer to the cortical bone is lowered by 60.47% with single-pitch microthread.
Conclusion: Single-pitch microthread dissipates lesser stresses to cortical bone while the implant body, abutment, and superstructure absorb more stress. This will have a positive influence on the bone-implant contact and contribute to preservation of crestal bone. Implant with single pitch microthread will thus be preferable to be used in areas where the amount of cortical bone available is less.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4163828 | PMC |
J Radiosurg SBRT
January 2024
College of Medicine, California Northstate University, Elk Grove, CA, USA.
Purpose: Precision targeting is crucial to successful stereotactic radiosurgery for trigeminal neuralgia (TGN). We investigated the impact of intra-fractional 6-dimensional corrections during frameless image-guided radiosurgery (IGRS) for pain outcome in TGN patients.
Materials And Methods: A total of 41 sets of intra-fractional corrections from 35 patients with TGN treated by frameless IGRS from 2009 to 2013 were retrospectively studied.
Radiother Oncol
September 2023
Department of Radiotherapy, UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium.
Background: Single-isocenter linac-based stereotactic radiosurgery (SRS) has emerged as a dedicated treatment option for multiple brain metastases. Consequently, image-guidance for patient positioning and motion management has become very important. The purpose of this study was to analyze intra-fraction errors measured with stereoscopic x-rays and their impact on the dose distribution.
View Article and Find Full Text PDFInt J Oral Maxillofac Surg
October 2023
Oral and Maxillofacial Surgery Service, Glasgow University Dental Hospital and School, Glasgow, UK. Electronic address:
The digital articulation of dental models is gradually replacing the conventional physical approach for occlusal prediction planning. This study was performed to compare the accuracy and reproducibility of free-hand articulation of two groups of digital and physical dental models, 12 Class I (group 1) and 12 Class III (group 2). The models were scanned using an intraoral scanner.
View Article and Find Full Text PDFPhys Med Biol
August 2017
Central Research Laboratory, Hamamatsu Photonics K.K., 5000, Hirakuchi, Hamakita-ku, Hamamatsu City 434-8601, Japan.
A high-resolution positron emission tomography (PET) scanner, dedicated to brain studies, was developed and its performance was evaluated. A four-layer depth of interaction detector was designed containing five detector units axially lined up per layer board. Each of the detector units consists of a finely segmented (1.
View Article and Find Full Text PDFMed Phys
December 2014
Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637-1470.
Purpose: The use of medical technology capable of tracking patient motion or positioning patients along 6 degree-of-freedom (6DOF) has steadily increased in the field of radiation therapy. However, due to the complex nature of tracking and performing 6DOF motion, it is critical that such technology is properly verified to be operating within specifications in order to ensure patient safety. In this study, a robotic motion phantom is presented that can be programmed to perform highly accurate motion along any X (left-right), Y (superior-inferior), Z (anterior-posterior), pitch (around X), roll (around Y), and yaw (around Z) axes.