Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Telavancin is a semisynthetic lipoglycopeptide with a dual mechanism of action against Gram-positive pathogens. Two brief reports have suggested potential cross-reactivity of telavancin with the vancomycin particle-enhanced turbidometric immunoassay (PETIA). The purpose of this study was to evaluate several commercially available vancomycin immunoassays (fluorescence polarization [FPIA], enzyme-multiplied immunoassays [EMIT], PETIA, and chemiluminescent immunoassay [CMIA]) for cross-reactivity with telavancin. Seven sites were selected to analyze serum samples for vancomycin. Each site received a set of samples (n = 18) which combined drug-free serum with telavancin, 7-OH telavancin metabolite, or vancomycin. Immunoassays demonstrating potential cross-reactivity were further evaluated by sending a duplicate sample set to multiple laboratories. Cross-reactivity was defined as the percent theoretical concentration (reported concentration/theoretical concentration × 100). No cross-reactivity was seen with FPIA or EMIT. Within the theoretical concentration range of 5 to 120 μg/ml of telavancin, the Synchron PETIA system reported vancomycin concentrations ranging from 4.7 to 54.2 μg/ml compared to vancomycin concentrations from 1.1 to 5.6 μg/ml for the Vista PETIA system. The Architect CMIA system reported vancomycin concentrations in the range of 0.27 to 0.97 μg/ml, whereas Advia Centaur XP CMIA reported vancomycin concentrations between 1.6 and 31.6 μg/ml. The Architect CMIA immunoassay had the lowest percent cross-reactivity (0.8 to 5.4%), while the Synchron PETIA immunoassay demonstrated the highest percent cross-reactivity (45.2 to 53.8%). Telavancin samples measured by liquid chromatography-mass spectroscopy were within 93.9 to 122% of theoretical concentrations. Vancomycin concentrations were not measured in any 7-OH telavancin-spiked sample. Vancomycin concentrations measured by liquid chromatography-mass spectroscopy were within 57.2 to 113% of theoretical concentrations. PETIA and CMIA measured vancomycin concentrations in telavancin-spiked samples. Significant variability in percent cross-reactivity was observed for each platform regardless of immunoassay method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4249549 | PMC |
http://dx.doi.org/10.1128/AAC.03785-14 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!