Microvascular quantification based on contour-scanning photoacoustic microscopy.

J Biomed Opt

Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, One Brookings Drive, St. Louis, Missouri 63130, United States.

Published: September 2014

Accurate quantification of microvasculature remains of interest in fundamental pathophysiological studies and clinical trials. Current photoacoustic microscopy can noninvasively quantify properties of the microvasculature, including vessel density and diameter, with a high spatial resolution. However, the depth range of focus (i.e., focal zone) of optical-resolution photoacoustic microscopy (OR-PAM) is often insufficient to encompass the depth variations of features of interest—such as blood vessels—due to uneven tissue surfaces. Thus, time-consuming image acquisitions at multiple different focal planes are required to maintain the region of interest in the focal zone. We have developed continuous three-dimensional motorized contour-scanning OR-PAM, which enables real-time adjustment of the focal plane to track the vessels’ profile. We have experimentally demonstrated that contour scanning improves the signal-to-noise ratio of conventional OR-PAM by as much as 41% and shortens the image acquisition time by 3.2 times. Moreover, contour-scanning OR-PAM more accurately quantifies vessel density and diameter, and has been applied to studying tumors with uneven surfaces.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4164706PMC
http://dx.doi.org/10.1117/1.JBO.19.9.096011DOI Listing

Publication Analysis

Top Keywords

photoacoustic microscopy
12
vessel density
8
density diameter
8
focal zone
8
contour-scanning or-pam
8
microvascular quantification
4
quantification based
4
based contour-scanning
4
contour-scanning photoacoustic
4
microscopy accurate
4

Similar Publications

Fluoropolymer-Single Crystal Nanocomposite Based Transducer Fabrication for Bio-Imaging.

Adv Healthc Mater

January 2025

Department of Physical Sciences, Indian Institute of Science Education and Research Mohali, Knowledge City, Sector 81, SAS Nagar, Manauli, 140306, India.

Fluoropolymer alone, as an alternative to lead-based piezoelectric materials, has shown multiple challenges to develop useful sensors for solving real-world problems such as photoacoustic, ultrasound pulse echo, and other non-destructive testing. This work demonstrates the fabrication of high frequency and wide bandwidth transducers with fluoropolymer and highly polarizing cubic single crystal Barium titanate (BaTiO) ceramic composite for high resolution in-vivo photo-acoustic and ultrasound imaging. For transducer fabrication, a customized bio-compatible nanocomposite sensor film of PVDF-TrFE (Polyvinylidene fluoride trifluoroethylene)/BaTiO (BTO) is synthesized by drop and dry in heating-cum-electro-poling system for advancing polarization, crystallinity, and higher charge generation.

View Article and Find Full Text PDF

Photoacoustic microscopy has demonstrated outstanding performance in high-resolution functional imaging. However, in the process of photoacoustic imaging, the photoacoustic signals will be polluted by inevitable background noise. Besides, the image quality is compromised due to the biosafety limitation of the laser.

View Article and Find Full Text PDF

Tracking Liver Fibrosis with Photoacoustic Microscopy.

Radiology

January 2025

Department of Biomedical Engineering, Duke University, 100 Science Dr, Hudson Hall Annex 260, Durham, NC 27710.

View Article and Find Full Text PDF

Quantification of Vascular Remodeling and Sinusoidal Capillarization to Assess Liver Fibrosis with Photoacoustic Imaging.

Radiology

January 2025

From the Department of Radiology, The Third Affiliated Hospital of Southern Medical University (Academy of Orthopedics, Guangdong Province), Guangzhou, China (W.L., L.S., R.Z., Y.Z.); and Medical Research Center, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Southern Medical University, Zhongshan 2nd Rd, Yuexiu District, Guangzhou 510000, People's Republic of China (J.L., H.L., X.Z., F.X., T.S., K.L., L.N.).

Background Photoacoustic microscopy (PAM) can be used to detect strong absorption from endogenous and exogenous contrast material, making it promising for detailed structural and functional imaging of hepatic sinusoids, including dynamic visualization of permeability. Purpose To evaluate whether PAM-based quantitative parameters of liver function and integrity (lacunarity, blood oxygen saturation [Sao], and Evans blue [EB] permeability) are associated with histopathologic indexes of fibrosis in a mouse model. Materials and Methods Between October 2022 and July 2023, a total of 35 male C57BL/6 mice were included in this study and received intraperitoneal injection of carbon tetrachloride to establish mouse models of progressive liver fibrosis, with seven mice in each group.

View Article and Find Full Text PDF

Low-cost microvascular phantom for photoacoustic imaging using loofah.

J Biomed Opt

January 2025

Washington University in St. Louis, Department of Biomedical Engineering, St. Louis, Missouri, United States.

Significance: Existing photoacoustic phantoms are unable to mimic complex microvascular structures with varying sizes and distributions. A suitable material with structures that mimic intricate microvascular networks is needed.

Aim: Our aim is to introduce loofah as a natural phantom material with complex fiber networks ranging from 50 to , enabling the fabrication of phantoms with controlled optical properties comparable to those of human microvasculature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!