Fiber-reinforced composites (FRC) could be feasible materials for fracture fixation devices if the mechanical properties of the composites are congruent with the local structural properties of bone. In a recently developed FRC implant, bisphenol A dimethacrylate (BisGMA) and triethylene glycol dimethacrylate (TEGDMA) resin was reinforced with unidirectional E-glass fibers. The addition of a braided glass fiber sleeving to the unidirectional fibers increased the torsional strength (99.5MPa) of the FRC implants at the expense of the flexural strength (602.0MPa). The flexural modulus was 15.3GPa. Two types of FRC intramedullary nails were prepared; first type was FRC as such, second type was FRC with a surface layer of bioactive glass (BG) granules. Experimental oblong subtrochanteric defect was created in 14 rabbits. The defect, which reduced the torsional strength of the bones by 66%, was fixed with an FRC intramedullary nail of either type. The contralateral intact femur served as the control. This model simulated surgical stabilization of bone metastasis. After 12 weeks of follow-up, the femurs were harvested and analyzed by torsional testing, micro-CT and hard tissue histology. Healed undisplaced peri-implant fractures were noticed in half of the animals irrespective of the type of FRC implant. Torsional testing showed no significant differences between the implantation groups. The torsional strength of the bones stabilized by either type of FRC implant was 83% of that of the contralateral femurs. In histological analysis, no implant debris and no adverse tissue reactions were observed. While the mechanical properties of the modified FRCs were suboptimal, the FRC intramedullary nails supported the femurs without structural failure, even in the cases of peri-implant fractures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmbbm.2014.08.020 | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Dental and Life Science Institute, Pusan National University, Yangsan, Korea.
Background: This study compared the torsional resistance, bending stiffness, and cyclic fatigue resistances of different heat-treated NiTi files for minimally invasive instrumentation.
Methods: TruNatomy (TN) and EndoRoad (ER) file systems were compared with ProTaper Gold (PG). Torsional load, distortion angle, and bending stiffness were assessed using a custom device AEndoS, and toughness was calculated using the torsional data.
BMC Oral Health
January 2025
Department of Conservative Dentistry, College of Dentistry, Kyung Hee University, 26-6, Kyungheedae-ro, Dongdaemun-gu, Seoul, 02453, Republic of Korea.
Background: This study aims to compare design, phase transformation behavior, and torsional resistance of the ProGlider (PG) and ProTaper ultimate slider (PUS) and to compare the performance of two files in the glide-path preparation of a double-curved artificial canal.
Methods: Scanning electron microscopy, micro-computed tomography, and differential scanning calorimetry were used to characterize the samples. A torsional resistance test was performed to obtain ultimate strength and distortion angle.
Biomater Adv
January 2025
Department of Chemistry, Materials and Chemical Engineering G. Natta, Politecnico di Milano, Piazza Leonardo Da Vinci 32, Milan, Italy; Local Unit Politecnico di Milano, Milan, Italy. Electronic address:
Microtia, along with trauma, represents one of the main causes of external ear malformation. Different clinical techniques were developed for the reconstruction of the auricle, but they all have some drawbacks. This work is focused on the development of an innovative 3D porous scaffold, printed by Fused Deposition Modelling (FDM) and based on laser-scanned images of the healthy contralateral ear of the patient.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Department of Design and Engineering, Faculty of Science and Technology, Bournemouth University, Poole, Dorset BH12 5BB, UK.
This study explores the impact of short-term annealing on the thermal stability and mechanical properties of oxygen-free copper subjected to high-pressure torsion (HPT). Copper samples were deformed through HPT with varying numbers of turns at room temperature and subsequently subjected to short-term annealing at temperatures of 398 K and 423 K. Microstructural analysis revealed that annealing led to grain growth and a reduction in dislocation density, with samples processed with fewer HPT turns exhibiting more significant grain coarsening.