A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Methamphetamine and amphetamine isomer concentrations in human urine following controlled Vicks VapoInhaler administration. | LitMetric

Methamphetamine and amphetamine isomer concentrations in human urine following controlled Vicks VapoInhaler administration.

J Anal Toxicol

Chemistry and Drug Metabolism, Intramural Research Program, National Institute on Drug Abuse, National Institutes of Health, 251 Bayview Blvd., Suite 200 Room 05A-721, Baltimore, MD 21224, USA

Published: October 2014

AI Article Synopsis

  • Legitimate use of legal intranasal decongestants like Vicks VapoInhaler can create confusion for urine drug tests, potentially resulting in false positives for amphetamines.
  • In a study of 22 healthy adults using the inhaler, no d-methamphetamine or d-amphetamine was detected in urine specimens, affirming that the decongestant doesn't significantly affect drug test results for those specific substances.
  • However, one type of immunoassay, EMIT(®) II Plus, resulted in a small percentage (2.2%) of false-positive readings, indicating that while most tests are reliable, there are exceptions that may necessitate further testing.

Article Abstract

Legitimate use of legal intranasal decongestants containing l-methamphetamine may complicate interpretation of urine drug tests positive for amphetamines. Our study hypotheses were that commonly used immunoassays would produce no false-positive results and a recently developed enantiomer-specific gas chromatography-mass spectrometry (GC-MS) procedure would find no d-amphetamine or d-methamphetamine in urine following controlled Vicks VapoInhaler administration at manufacturer's recommended doses. To evaluate these hypotheses, 22 healthy adults were each administered one dose (two inhalations in each nostril) of a Vicks VapoInhaler every 2 h for 10 h on Day 1 (six doses), followed by a single dose on Day 2. Every urine specimen was collected as an individual void for 32 h after the first dose and assayed for d- and l-amphetamines specific isomers with a GC-MS method with >99% purity of R-(-)-α-methoxy-α-(trifluoromethyl)phenylacetyl derivatives and 10 µg/L lower limits of quantification. No d-methamphetamine or d-amphetamine was detected in any urine specimen by GC-MS. The median l-methamphetamine maximum concentration was 62.8 µg/L (range: 11.0-1,440). Only two subjects had detectable l-amphetamine, with maximum concentrations coinciding with l-methamphetamine peak levels, and always ≤ 4% of the parent's maximum. Three commercial immunoassays for amphetamines EMIT(®) II Plus, KIMS(®) II and DRI(®) had sensitivities, specificities and efficiencies of 100, 97.8, 97.8; 100, 99.6, 99.6 and 100, 100, 100%, respectively. The immunoassays had high efficiencies, but our first hypothesis was not affirmed. The EMIT(®) II Plus assay produced 2.2% false-positive results, requiring an enantiomer-specific confirmation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4168291PMC
http://dx.doi.org/10.1093/jat/bku077DOI Listing

Publication Analysis

Top Keywords

vicks vapoinhaler
12
urine controlled
8
controlled vicks
8
vapoinhaler administration
8
urine specimen
8
urine
5
methamphetamine amphetamine
4
amphetamine isomer
4
isomer concentrations
4
concentrations human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!