Article Abstract

Micellar electrokinetic chromatography (MEKC) has been applied for the determination of 5-hydroxymethylfurfural in several foodstuffs. A 75mM phosphate buffer solution at pH 8.0 containing 100mM sodium dodecylsulphate was used as background electrolyte (BGE), and the separation was performed by applying +25kV in a 50μm I.D. uncoated fused-silica capillary. Good linearity over the range 2.5-250mgkg(-1) (r(2)⩾0.999) and run-to-run and day-to-day precisions at low and medium concentration levels were obtained. Sample limit of detection (0.7mgkg(-1)) and limit of quantification (2.5mgkg(-1)) were established by preparing the standards in blank matrix. The procedure was validated by comparing the results with those obtained with liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Levels of HMF in 45 different foodstuffs such as breakfast cereals, toasts, honey, orange juice, apple juice, jam, coffee, chocolate and biscuits were determined.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2010.12.016DOI Listing

Publication Analysis

Top Keywords

micellar electrokinetic
8
electrokinetic chromatography
8
5-hydroxymethylfurfural content
4
content foodstuffs
4
foodstuffs determined
4
determined micellar
4
chromatography micellar
4
chromatography mekc
4
mekc applied
4
applied determination
4

Similar Publications

A review of emerging techniques for pyrethroid residue detection in agricultural commodities.

Heliyon

January 2025

Laboratory of Vaccine and Biomolecules, Institute of Bioscience, Universiti Putra Malaysia, 43400, UPM Serdang, Selangor, Malaysia.

Pyrethroid pesticides are essential for modern agriculture, helping to control pests and protect crops. However, due to growing concerns about their potential impact on human health and the environment, reliable detection methods are essential to ensure food safety. In this literature review, we explore the techniques used over the past decade to detect pyrethroid residues in agricultural products.

View Article and Find Full Text PDF

The cosmetics industry is one of the fastest-growing sectors worldwide. The dynamic evolution of this industry results in an increasingly diverse range of products containing various active ingredients. Ensuring the quality of these products is crucial for consumer safety, necessitating the use of advanced analytical methods and adherence to legal regulations.

View Article and Find Full Text PDF

Background: Capillary electrophoresis (CE) is a highly versatile separation technique widely used in analytical chemistry. Traditionally, CE can be categorized as either aqueous or non-aqueous systems based on the buffer solvents employed. For decades, non-aqueous CE has been predominantly associated with the use of organic solvents, a perception deeply ingrained in the scientific community.

View Article and Find Full Text PDF

A rapid and sensitive enrichment technique, field enhanced sample injection-dynamic pH junction-sweeping (FESI-DypH-sweeping) was successfully developed for the simultaneous separation and concentration of alkaloids and stereoisomers of Uncariae ramulus cum uncis (UR) by cyclodextrin electrokinetic chromatography (CDEKC) with diode array detection system. The sample was prepared in a low-conductivity (FESI), low-pH (DypH) sample matrix (4 mM phosphate buffer, 3% methanol, pH=3), and the background electrolyte (BGE) consisted of a high-conductivity, high-pH buffer (40 mM phosphate buffer, pH 7.0, 8 mg/mL carboxymethyl-β-cyclodextrin, and 30% methanol).

View Article and Find Full Text PDF

Human serum transferrin can bind up to two iron atoms, one in each of its two domains which are known as the N-lobe and the C-lobe. Ferric pyrophosphate and ferric citrate have been shown to direct loading into the C-lobe and N-lobe, respectively. We report that the iron supplement ferric pyrophosphate citrate directs iron to the C-lobe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!