A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Applying shear stress to endothelial cells in a new perfusion chamber: hydrodynamic analysis. | LitMetric

Applying shear stress to endothelial cells in a new perfusion chamber: hydrodynamic analysis.

J Artif Organs

Department of Chemical Engineering, Faculty of Engineering, University of Tehran, No. 4, Orooji Alley, 16 Azar St, Enqelab Ave, P.O. Box 11365-45, Tehran, Iran,

Published: December 2014

Perfusion bioreactors have been proved to be an impartible part of vascular tissue engineering due to its broad range of applications as a means to distribute nutrients within porous scaffold along with providing appropriate physical and mechanical stimuli. To better understand the mechanical phenomena inside a bioreactor, computational fluid dynamics (CFD) was adopted followed by a validation technique. The fluid dynamics of the media inside the bioreactor was modeled using the Navier-Stokes equation for incompressible fluids while convection through the scaffold was described by Brinkman's extension of Darcy's law for porous media. Flow within the reactor determined the orientation of endothelial cells on the scaffold. To validate flow patterns, streamlines and shear stresses, colorimetry technique was used following attained results from CFD. Our bioreactor was modeled to simulate the optimum condition and flow patterns over scaffold to culture ECs for in vitro experimentation. In such experiments, cells were attached firmly without significant detachment and more noticeably elongation process was triggered even shortly after start up.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-014-0790-0DOI Listing

Publication Analysis

Top Keywords

endothelial cells
8
inside bioreactor
8
fluid dynamics
8
bioreactor modeled
8
flow patterns
8
applying shear
4
shear stress
4
stress endothelial
4
cells perfusion
4
perfusion chamber
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!