Growing evidence suggests that the nervous system contributes to non-contact knee ligament injury, but limited evidence has measured the effect of extrinsic events on joint stability. Following unanticipated events, the startle reflex leads to universal stiffening of the limbs, but no studies have investigated how an acoustic startle influences knee stiffness and muscle activation during a dynamic knee perturbation. Thirty-six individuals were tested for knee stiffness and muscle activation of the quadriceps and hamstrings. Subjects were seated and instructed to resist a 40-degree knee flexion perturbation from a relaxed state. During some trials, an acoustic startle (50 ms, 1000 Hz, 100 dB) was applied 100 ms prior to the perturbation. Knee stiffness, muscle amplitude, and timing were quantified across time, muscle, and startle conditions. The acoustic startle increased short-range (no startle: 0.044 ± 0.011 N·m/deg/kg; average startle: 0.047 ± 0.01 N·m/deg/kg) and total knee stiffness (no startle: 0.036 ± 0.01 N·m/deg/kg; first startle 0.027 ± 0.02 N·m/deg/kg). Additionally, the startle contributed to decreased [vastus medialis (VM): 13.76 ± 33.6%; vastus lateralis (VL): 6.72 ± 37.4%] but earlier (VM: 0.133 ± 0.17 s; VL: 0.124 ± 0.17 s) activation of the quadriceps muscles. The results of this study indicate that the startle response can significantly disrupt knee stiffness regulation required to maintain joint stability. Further studies should explore the role of unanticipated events on unintentional injury.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/sms.12315 | DOI Listing |
J Biomech
January 2025
Exercise Biochemistry Laboratory, Department of Biochemistry and Molecular Biology, Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul, Brazil.
Understanding intrinsic muscular adaptations more deeply can help clarify their relationships with sports performance. Therefore, the aim of this study was to determine if vastus lateralis muscle architecture, quality and stiffness can explain knee extensor maximal torque and countermovement and squat jump performance of athletes. One hundred and two athletes were evaluated based on the architecture, quality and stiffness of the vastus lateralis at rest.
View Article and Find Full Text PDFPLoS One
January 2025
Laboratory for Biomechanics and Biomaterials, Department of Orthopedic Surgery, DIAKOVERE Annastift, Hannover Medical School, Hannover, Germany.
Prosthetic gait differs considerably from the unimpaired gait. Studying alterations in the gait patterns could help to understand different adaptation mechanisms adopted by these populations. This study investigated the effects of induced stiff-knee gait (SKG) on prosthetic and healthy gait patterns and the capabilities of predictive simulation.
View Article and Find Full Text PDFWith an estimated incidence of 0.02% to 0.2%, multiligamentous knee injuries are rare, often devastating injuries that can occur with concomitant vascular or neurologic involvement.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
December 2024
Hospital Particular do Algarve, Gambelas, Portugal.
Purpose: This study aims to illustrate the assessment and treatment strategies of acute and chronic deltoid ligament injuries, providing a treatment algorithm for each scenario.
Methods: A retrospective review was conducted on 39 patients, who had either an acute deltoid ligament injury or suffered chronic deltoid ligament insufficiency. All patients were operated on between January 2016 and December 2022.
J Neuroeng Rehabil
December 2024
Chair of Autonomous Systems and Mechatronics, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.
Wearable robots are often powered by elastic actuators, which can mimic the intrinsic compliance observed in human joints, contributing to safe and seamless interaction. However, due to their increased complexity, when compared to direct drives, elastic actuators are susceptible to faults, which pose significant challenges, potentially compromising user experience and safety during interaction. In this article, we developed a fault-tolerant control strategy for torque assistance in a knee exoskeleton and investigated user experience during a walking task while emulating faults.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!