A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of microdialysis-based continuous glucose monitoring to drive real-time semi-closed-loop insulin infusion. | LitMetric

Continuous glucose monitoring (CGM) and automated insulin delivery may make diabetes management substantially easier, if the quality of the resulting therapy remains adequate. In this study, a semi-closed-loop control algorithm was used to drive insulin therapy and its quality was compared to that of subject-directed therapy. Twelve subjects stayed at the study site for approximately 70 hours and were provided with the investigational Automated Pancreas System Test Stand (APS-TS), which was used to calculate insulin dosage recommendations automatically. These recommendations were based on microdialysis CGM values and common diabetes therapy parameters. For the first half of their stay, the subjects directed their diabetes therapy themselves, whereas for the second half, the insulin recommendations were delivered by the APS-TS (so-called algorithm-driven therapy). During subject-directed therapy, the mean glucose was 114 mg/dl compared to 125 mg/dl during algorithm-driven therapy. Time in target (90 to 150 mg/dl) was approximately 46% during subject-directed therapy and approximately 58% during algorithm-driven therapy. When subjects directed their therapy, approximately 2 times more hypoglycemia interventions (oral administration of carbohydrates) were required than during algorithm-driven therapy. No hyperglycemia interventions (delivery of addition insulin) were necessary during subject-directed therapy, while during algorithm-driven therapy, 2 hyperglycemia interventions were necessary. The APS-TS was able to adequately control glucose concentrations in the subjects. Time in target was at least comparable or moderately higher during closed-loop control and markedly fewer hypoglycemia interventions were required, thus increasing patient safety.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4455459PMC
http://dx.doi.org/10.1177/1932296814549828DOI Listing

Publication Analysis

Top Keywords

algorithm-driven therapy
20
subject-directed therapy
16
therapy
14
continuous glucose
8
glucose monitoring
8
diabetes therapy
8
subjects directed
8
time target
8
hypoglycemia interventions
8
therapy hyperglycemia
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!