AI Article Synopsis

  • The study aimed to assess the effectiveness of a single vial kit for labeling DTPA-bis-methionine with a radioactive tracer ([99m]Tc) in detecting primary breast cancer in patients.
  • Thirty female patients, all showing signs of breast cancer, underwent imaging tests after receiving the radiotracer, with results showing high accuracy in identifying cancerous lesions.
  • The findings suggest that the DTPA-bis-MET kit is a promising and easily produced option for breast cancer detection, offering significant diagnostic potential compared to traditional methods.

Article Abstract

Objective: To evaluate the diagnostic utility of a single vial ready to label with [99m]Tc kit preparation of DTPA-bis-methionine (DTPA-bis-MET) for the detection of primary breast cancer.

Methods: The conjugate (DTPA-bis-MET) was synthesized by covalently conjugating two molecules of methionine to DTPA and formulated as a single vial ready to label with [99m]Tc lyophilized kit preparations. Thirty female patients (mean age=47.5±11.8 years; range=21-69 years) with radiological/clinical evidence of having primary breast carcinoma were subjected to [99m]Tc-methionine scintigraphy. The whole body (anterior and posterior) imaging was performed on all the patients at 5 minutes, 10 minutes, 1 hour, 2 hours, and 4 hours following an intravenous administration of 555-740 MBq radioactivity of [99m]Tc-methionine. In addition, scintimammography (static images; 256×256 matrix) at 1, 2, and 4 hours was also performed on all the patients.

Results: The resultant radiolabel, that is, [99m]Tc-DTPA-bis-MET, yielded high radiolabeling efficiency (>97.0%), radiochemical purity (166-296 MBq/μmol), and shelf life (>3 months). The radiotracer primarily gets excreted through the kidneys and localizes in the breast cancer lesions with high target-to-nontarget ratios. The mean±SD ratios on the scan-positive lesions acquired at 1, 2, and 4 hours postinjection were 3.6±0.48, 3.10±0.24, and 2.5±0.4, respectively. [99m]Tc-methionine scintimammography demonstrated an excellent sensitivity and positive predictive value of 96.0% each for the detection of primary breast cancer.

Conclusion: Ready to label single vial kit formulations of DTPA-bis-MET can be easily synthesized as in-house production and conveniently used for the scintigraphic detection of breast cancer and other methionine-dependent tumors expressing the L-type amino acid transporter-1 receptor. The imaging technique thus could be a potential substitute for the conventional single-photon emission computed tomography (SPECT)-based tumor imaging agents, especially for tracers with nonspecific mitochondrial uptake. However, the diagnostic efficacy of [99m]Tc-methionine needs to be evaluated in a large cohort of patients through further multicentric trials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4158983PMC
http://dx.doi.org/10.1089/cbr.2014.1655DOI Listing

Publication Analysis

Top Keywords

primary breast
16
single vial
16
breast cancer
12
ready label
12
vial kit
8
kit preparation
8
vial ready
8
label [99m]tc
8
detection primary
8
breast
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?