Because of their chemical properties and multiday half lives, iodine-124 and zirconium-89 are being used in a growing number of PET imaging studies. Some aspects of their quantitation, however, still need attention. For (89)Zr the PET images should, in principle, be as quantitatively accurate as similarly reconstructed 18F measurements. We found, however, that images of a 20 cm well calibration phantom containing (89)Zr underestimated the activity by approximately 10% relative to a dose calibrator measurement (Capintec CRC-15R) using a published calibration setting number of 465. PET images of (124)I, in contrast, are complicated by the contribution of decays in cascade that add spurious coincident events to the PET data. When these cascade coincidences are properly accounted for, quantitatively accurate images should be possible. We found, however, that even with this correction we still encountered what appeared to be a large variability in the accuracy of the PET images when compared to dose calibrator measurements made using the calibration setting number, 570, recommended by Capintec. We derive new calibration setting numbers for (89)Zr and (124)I based on their 511 keV photon peaks as measured on an HPGe detector. The peaks were calibrated relative to an 18F standard, the activity level of which was precisely measured in a dose calibrator under well-defined measurement conditions. When measuring (89)Zr on a Capintec CRC-15R we propose the use of calibration setting number 517. And for (124)I, we recommend the use of a copper filter surrounding the sample and the use of calibration setting number 494. The new dose calibrator measurement procedures we propose will result in more consistent and accurate radioactivity measurements of (89)Zr and (124)I. These and other positron emitting radionuclides can be accurately calibrated relative to 18F based on measurements of their 511 keV peaks and knowledge of their relative positron abundances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4159273PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0106868PLOS

Publication Analysis

Top Keywords

dose calibrator
20
calibration setting
20
setting number
16
calibrator measurement
12
89zr 124i
12
pet images
12
measurement procedures
8
quantitatively accurate
8
capintec crc-15r
8
511 kev
8

Similar Publications

Importance: Caries is the most common chronic childhood disease, with substantial health disparities.

Objective: To test whether parent-targeted oral health text (OHT) messages outperform child wellness text (CWT) messages on pediatric caries increment and oral health behaviors among underserved children attending pediatric well-child visits.

Design, Setting, And Participants: The parallel randomized clinical trial, Interactive Parent-Targeted Text Messaging in Pediatric Clinics to Reduce Caries Among Urban Children (iSmile), included participants who were recruited during pediatric medical clinic visits at 4 sites in Boston, Massachusetts, that serve low-income and racially and ethnically diverse (herein, underserved) populations.

View Article and Find Full Text PDF

Background: The combination of immune checkpoint inhibitors (ICIs) and radiotherapy (RT) may increase the risk of radiation esophagitis (RE). This study aimed to establish and validate a new nomogram to predict RE in patients with non-small cell lung cancer (NSCLC) undergoing immunochemotherapy followed by RT (ICI-RT).

Methods: The 102 eligible patients with NSCLC treated with ICI-RT were divided into training (n = 71) and validation (n = 31) cohorts.

View Article and Find Full Text PDF

Bioanalysis of protein-unbound prednisolone in serum using equilibrium dialysis followed by liquid chromatography-tandem mass spectrometry.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Department of Clinical Diagnostics, University Medical Centre Utrecht, Utrecht University, Utrecht, The Netherlands. Electronic address:

Introduction: High-dose systemic prednisolone is the cornerstone treatment of many autoimmune- and inflammatory diseases. Since prednisolone shows non-linear protein binding at higher serum concentrations, quantification of the unbound prednisolone concentration is important to understand prednisolone pharmacokinetics. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to quantify protein-unbound prednisolone in serum.

View Article and Find Full Text PDF

Balanced nutrition will be rewarding to profitable and sustainable yield of Kodo millet. In this context, soil test crop response (STCR) experiments on kodo millet were conducted from 2020 to 2022 to assess relationships between yield, soil, plant, and fertilizer nitrogen (N), phosphorus (P), and potassium (K) and calibrate optimum nutrient doses for attaining yield targets. The Basic parameters, i.

View Article and Find Full Text PDF

Purpose: Tuberculosis meningitis (TBM) has emerged as the most lethal type of disease. The prognosis of meningitis is often related to disease severity and early therapeutic intervention.

Methods: Patients were screened for primary TBM and received a quadruple regimen comprising isoniazid (standard dose of 300 mg/day and high dose of 600 mg/day), rifampin, ethambutol, and pyrazinamide.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!