Hippocampal volume is a promising biomarker to enhance the accuracy of the diagnosis of dementia due to Alzheimer's disease (AD). However, whereas hippocampal volume is well studied in patient samples from clinical trials, its value in clinical routine patient care is still rather unclear. The aim of the present study, therefore, was to evaluate fully automated atlas-based hippocampal volumetry for detection of AD in the setting of a secondary care expert memory clinic for outpatients. One-hundred consecutive patients with memory complaints were clinically evaluated and categorized into three diagnostic groups: AD, intermediate AD, and non-AD. A software tool based on open source software (Statistical Parametric Mapping SPM8) was employed for fully automated tissue segmentation and stereotactical normalization of high-resolution three-dimensional T1-weighted magnetic resonance images. Predefined standard masks were used for computation of grey matter volume of the left and right hippocampus which then was scaled to the patient's total grey matter volume. The right hippocampal volume provided an area under the receiver operating characteristic curve of 84% for detection of AD patients in the whole sample. This indicates that fully automated MR-based hippocampal volumetry fulfills the requirements for a relevant core feasible biomarker for detection of AD in everyday patient care in a secondary care memory clinic for outpatients. The software used in the present study has been made freely available as an SPM8 toolbox. It is robust and fast so that it is easily integrated into routine workflow.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3233/JAD-141446 | DOI Listing |
PLoS One
January 2025
Trinity Centre for Biomedical Engineering, Trinity College Dublin, Dublin, Ireland.
Electroencephalographic signals are obtained by amplifying and recording the brain's spontaneous biological potential using electrodes positioned on the scalp. While proven to help find changes in brain activity with a high temporal resolution, such signals are contaminated by non-stationary and frequent artefacts. A plethora of noise reduction techniques have been developed, achieving remarkable performance.
View Article and Find Full Text PDFInquiry
January 2025
The People's Hospital of Jianyang City, Jianyang, Sichuan Province, China.
This paper aims to establish an intelligent delivery system integrated with track logistics and explores its impact on the clinical transportation of goods. The study analyzed hospital delivery items before and after the implementation of an intelligent delivery system combined with automated track logistics in 2023. Delivery conditions prior to the system's activation served as the control group, while those post-implementation formed the observation group.
View Article and Find Full Text PDFFront Radiol
January 2025
Department of Biostatistics & Informatics, Colorado School of Public Health, Aurora, CO, United States.
In neuro-oncology, MR imaging is crucial for obtaining detailed brain images to identify neoplasms, plan treatment, guide surgical intervention, and monitor the tumor's response. Recent AI advances in neuroimaging have promising applications in neuro-oncology, including guiding clinical decisions and improving patient management. However, the lack of clarity on how AI arrives at predictions has hindered its clinical translation.
View Article and Find Full Text PDFSoft Matter
January 2025
Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Strasse 6, Dresden, 01069, Germany.
Field-induced microstructure evolution can play an important role in defining the coupled magneto-mechanical response of Magneto-Active Elastomers (MAEs). The behavior of these materials is classically modeled using mechanical, magnetic and coupled magneto-mechanical contributions to their free energy function. If the MAE sample is fully clamped so it cannot deform, the mechanical coupling is reduced to the internal microscopic deformations caused by the particles moving and deforming the elastic medium that surrounds them.
View Article and Find Full Text PDFNPJ Digit Med
January 2025
Technology & Innovation Hub, Shirley Ryan AbilityLab, Chicago, IL, USA.
Early screening and evaluation of infant motor development are crucial for detecting motor deficits and enabling timely interventions. Traditional clinical assessments are often subjective, without fully capturing infants' "real-world" behavior. This has sparked interest in portable, low-cost technologies to objectively and precisely measure infant motion at home, with a goal of enhancing ecological validity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!