Background: Transcatheter aortic valve implantation involves percutaneously implanting a biomechanical aortic valve to treat severe aortic stenosis. In order to select a proper device, precise sizing of the aortic valve annulus must be completed.
Methods: In this paper, we describe a fully automatic segmentation method to measure the aortic annulus diameter in patients with aortic calcification, operating on 3-dimensional transesophageal echocardiographic images. The method is based on state estimation of a subdivision surface representation of the left ventricular outflow tract and aortic root. The state estimation is solved by an extended Kalman filter driven by edge detections normal to the subdivision surface.
Results: The method was validated on echocardiographic recordings of 16 patients. Comparison against two manual measurements showed agreements (mean ±SD) of -0.3 ± 1.6 and -0.2 ± 2.3 mm for perimeter-derived diameters, compared to an interobserver agreement of -0.1 ± 2.1 mm.
Conclusions: With this study, we demonstrated the feasibility of an efficient and fully automatic measurement of the aortic annulus in patients with aortic disease. The algorithm robustly measured the aortic annulus diameter, providing measurements indistinguishable from those done by cardiologists.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4274687 | PMC |
http://dx.doi.org/10.1186/1471-2342-14-31 | DOI Listing |
Turk Kardiyol Dern Ars
January 2025
Department of Cardiology, Gülhane Faculty of Medicine, University of Health Sciences, Ankara, Türkiye.
Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan.
The Y-incision aortic annular enlargement (AAE) has been established as a safe and effective technique for upsizing the aortic annulus by 3 to 4 valve sizes. However, concerns have been raised regarding its technical complexity during reoperations, particularly given the extensive enlargement of the aortic annulus and root. We present a case of reoperative aortic valve replacement after previous Y-incision AAE for prosthetic valve endocarditis and aortic root abscess.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
September 2024
Section of Pediatric Cardiac Surgery, Morgan Stanley Children's Hospital, New York, New York.
Among repairs for ventriculoarterial discordance, ventricular septal defect, and pulmonary stenosis, aortic root translocation (Nikaidoh operation) offers the most anatomic result. With a diminutive pulmonary annulus or hypoplastic left ventricular outflow tract, the distance gained posteriorly with aortic translocation is negligible. We developed the "hemi-Nikaidoh" procedure as an alternative.
View Article and Find Full Text PDFJTCVS Open
December 2024
Department of Cardiac Surgery, Faculty of Medicine, Institute of Heart Diseases Clinical, Wroclaw Medical University, Wroclaw, Poland.
Pediatr Transplant
February 2025
The Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA.
Background: Partial heart transplantation (PHT) is a novel procedure for children in need of a growing valve replacement option. One challenge is identifying suitable donor valves. Semilunar heart valves from patients receiving a retransplant may be a source, however their functionality and growth potential especially at the time of retransplant are unknown.