Modelling and experimental validation of Textile Pockets based active inflatable device.

ISA Trans

LPMT laboratory (EA 4365), University of Haute-Alsace, 11 rue Alfred Werner F-68093 Mulhouse, France.

Published: November 2014

This paper aims with the mathematical modelling of an active inflatable device. This device is composed of a compressor, an Electro-pneumatic Pressure Converter (EPC) and an Inflatable Textile fabric Pocket (ITP). The later has interesting mechanical properties and is fabricated using Jacquard knitting technique which allows automatic production of unlimited varieties of pattern weaving without any mould. Thanks to these features, these ITPs have provided a better alternative to the classical airbags made by stretchable polymer material. The proposed mathematical model is obtained by combining sub-models of two main parts of the whole system. In this way, a generalised and flexible model is obtained which can easily take into consideration the ITPs of different shapes. The pressure dynamics inside the ITP are considered by taking into account the air flow rate, variation of the volume of ITP and the length of pneumatic lines joining ITP with compressed air source. The parameters of the whole mathematical model are obtained via identification techniques. The effectiveness of the model is assessed through several experimental tests with the help of a servo hydraulic fatigue testing machine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.isatra.2014.07.010DOI Listing

Publication Analysis

Top Keywords

active inflatable
8
inflatable device
8
mathematical model
8
modelling experimental
4
experimental validation
4
validation textile
4
textile pockets
4
pockets based
4
based active
4
device paper
4

Similar Publications

Modifying Informed Consent to Help Address Functional Unmasking in Psychedelic Clinical Trials.

JAMA Psychiatry

January 2025

Department of Psychiatry and Behavioral Sciences, Weill Institute for Neurosciences, University of California, San Francisco.

Importance: There is unprecedented clinician, industry, and patient interest in the therapeutic development of psychedelic drugs. This is due to a combination of promising clinical trial results, positive media coverage, and the lack of novel pharmacologic treatments for psychiatric disorders in recent decades. However, the field faces a key methodological challenge: masking participants to treatment conditions in psychedelic clinical trials has been largely unsuccessful.

View Article and Find Full Text PDF

Mitigating Data Leakage in a WiFi CSI Benchmark for Human Action Recognition.

Sensors (Basel)

December 2024

Nokia Bell Labs, 1082 Budapest, Hungary.

Human action recognition using WiFi channel state information (CSI) has gained attention due to its non-intrusive nature and potential applications in healthcare, smart environments, and security. However, the reliability of methods developed for CSI-based action recognition is often contingent on the quality of the datasets and evaluation protocols used. In this paper, we uncovered a critical data leakage issue, which arises from improper data partitioning, in a widely used WiFi CSI benchmark dataset.

View Article and Find Full Text PDF

Insertion of inflatable penile prosthesis (IPP) is generally regarded as a safe procedure, with low rates of complications. However, when complications do arise, they can pose significant challenges to both patients and surgeons. Patient optimization and adherence to specific intraoperative protocols are crucial in mitigating the risk of surgical complications.

View Article and Find Full Text PDF

Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.

View Article and Find Full Text PDF

Hypertension constitutes a significant risk factor for the development of many coronary artery diseases. In recent years, the advancement of technology and artificial intelligence has led to significant research and breakthroughs in wearable devices that can monitor blood pressure (BP). These devices offer continuous, real-time BP readings, facilitating the early detection and prevention of hypertension.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!