Purpose: To evaluate the efficacy of diode laser ablation of prostate for treating lower urinary tract symptoms (LUTS) in patients with locally advanced prostate cancer and comparing results with palli­ative transurethral resection of prostate (pTURP).

Materials And Methods: Thirty-six known cases of locally advanced prostate cancer with a maximum urinary flow rate (Qmax) of 12 mL per second or less and an International Prostate Symptom Score (IPSS) of 20 or more were included in this study. Patients were randomized into two groups. The first group underwent pTURP and for the second group diode laser ablation of prostate was done. In 6 months post-operative follow up, patients were evaluated for IPSS, post void residual (PVR) urine volume, Qmax and possible complications such as urethral stricture or urinary incontinence.

Results: Postoperatively, mean IPSS was 11.1 ± 4.1 in TURP group and 11.7 ± 3.6 in laser group (P = .64). Mean PVR was 18.4 ± 3.5 mL in TURP group and 17.7 ± 6.3 mL in laser group (P = .68). Mean Qmax in TURP and laser groups were measured 20.1 ± 4.5 mL/s and 19.4 ± 2.6 mL/s, respectively (P = .57). While there was a significant improvement in IPSS and Qmax and PVR in both groups, statisti­cal analysis did not show any significant difference postoperatively between pTURP and laser groups.

Conclusion: Diode laser ablation of prostate and pTURP, both improved significantly IPSS, PVR and Qmax. But hospital stay and post-operative catheterization time was less in laser group.

Download full-text PDF

Source

Publication Analysis

Top Keywords

diode laser
16
laser ablation
16
ablation prostate
16
prostate cancer
12
laser group
12
prostate
10
transurethral resection
8
resection prostate
8
laser
8
locally advanced
8

Similar Publications

Background: Caesarean section (CS) is the most common inpatient surgical procedure performed in Canada. CS is known to cause moderate-to-severe pain, which is suggested to be associated with postpartum depression and persistent pain. Existing limitations in multimodal analgesia and conscious attempts to avoid opioids highlight the need for non-pharmacological strategies.

View Article and Find Full Text PDF

Photobiomodulation (PBM) is a technology that has gained much attention in recent years regarding its potential application for stimulating wound healing, alleviating pain, reducing inflammation, and aiding in the restoration of function. Due to a scarcity of evidence in the literature regarding PBM for the treatment of burns, our objective of this study was to test whether treatment with PBM in hospitalized patients with second-degree burns accelerated recovery. A double-blind controlled study was conducted on nine patients with up to 15% second-degree burns who were hospitalized at Hadassah-Hebrew University Medical Center, Ein Kerem Campus, Jerusalem Israel, between July 2022 and November 2022.

View Article and Find Full Text PDF

Electronically Controlled Dual-Wavelength Switchable SRS Fiber Amplifier in the NIR-II Region for Multispectral Photoacoustic Microscopy.

Laser Photon Rev

October 2024

Harvard Medical School, Boston, MA 02114, USA; Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114, USA; Department of Cardiology, Erasmus Medical Center, Rotterdam GD3015, The Netherlands; Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02142, USA.

Photoacoustic microscopy (PAM) is a high-resolution and non-invasive imaging modality that provides optical absorption contrast. By employing dual- or multiple-wavelength excitation, PAM extends its capabilities to offer valuable spectroscopic information. To achieve efficient multispectral PAM imaging, an essential requirement is a light source characterized by a high repetition rate and switching rate, a ≈microjoule pulse energy, and a ≈nanosecond pulse duration.

View Article and Find Full Text PDF

Holographically designed aperiodic lattices (ALs) have proven to be an exciting engineering technique for achieving electrically switchable single- or multi-frequency emissions in terahertz (THz) semiconductor lasers. Here, we employ the nonlinear transfer matrix modeling method to investigate multi-wavelength nonlinear (sum- or difference-) frequency generation within an integrated THz (idler) laser cavity that also supports optical (pump and signal) waves. The laser cavity includes an aperiodic lattice, which engineers the idler photon lifetimes and effective refractive indices.

View Article and Find Full Text PDF

An ultra-narrow-linewidth laser is a core device in fields such as optical atomic clocks, quantum communications, and microwave photonic oscillators. This paper reports an ultra-narrow-linewidth self-injection locked semiconductor laser, which is realized through optical feedback from a high-Q (258 million) Fabry-Perot (FP) cavity constructed with three mirrors, generating an output power of 12 mW. Employing a delay self-heterodyne method based on a signal source analyzer, the phase noise of the laser is -129 dBc/Hz at 100 kHz offset frequency, with an intrinsic linewidth of 3 mHz.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!