A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Total spherical aberration of the cornea in patients with cataract. | LitMetric

Total spherical aberration of the cornea in patients with cataract.

Optom Vis Sci

*MD, PhD †MD Department of Surgical Sciences, Ophthalmology Institute, University of Turin, Turin, Italy (all authors).

Published: October 2014

Purpose: To investigate the distribution of corneal spherical aberration in patients with cataract using the Pentacam HR.

Methods: Consecutive cataract patients were examined using the Pentacam HR high-resolution rotating Scheimpflug camera (Oculus, Wetzlar, Germany). In one eye of each patient, the root-mean-square (RMS) of anterior, posterior, and total corneal spherical aberration Z4(0) was calculated by ray-tracing on an area of 6 mm diameter. The Pearson correlation coefficient (r) was used to assess correlations between Z4(0) RMS values and age/total corneal refractive power. The χ2 test was used to compare the proportion of eyes qualifying for spherically neutral or negatively aspheric (-0.17 and -0.27 μm) intraocular lenses (IOLs) by targeted level of residual spherical aberration.

Results: Fifty-seven men and 92 women were included (mean [±SD] age, 71.73 [±9.12] years). The RMS mean (±SD) values of Z4(0) were +0.353 (±0.132) μm, -0.121 (±0.034) μm, and +0.328 (±0.132) μm, respectively, for the anterior, posterior, and total cornea. The anterior, posterior, and total Z4(0) were on average significantly higher (p < 0.001) in women than in men. In both sexes, statistically significant (p < 0.05) age-related changes were found for the anterior and total Z4(0) but not for the posterior Z4(0) (p > 0.05). The total Z4(0) and total corneal refractive power were significantly correlated in men (p = 0.01) but not in women (p = 0.14). For postoperative targets of 0 ± 0.05/+0.10 ± 0.05 μm residual Z4(0), the proportion of eyes that would have qualified for implantation of negatively aspheric IOLs with -0.17 and with -0.27 μm was similar (61.1 and 56.3%, respectively; p = 0.09); significantly fewer eyes (6.7%) would have qualified for implantation of neutrally aspheric IOLs (p > 0.05).

Conclusions: Total corneal Z4(0) measured by Pentacam HR might be higher than that reported in previous studies. In most patients, the implantation of commercially available negatively aspheric IOLs would partially compensate for the positive total corneal Z4(0).

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000000380DOI Listing

Publication Analysis

Top Keywords

total corneal
16
spherical aberration
12
anterior posterior
12
posterior total
12
negatively aspheric
12
total z40
12
aspheric iols
12
z40
10
total
9
patients cataract
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!