Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate the distribution of corneal spherical aberration in patients with cataract using the Pentacam HR.
Methods: Consecutive cataract patients were examined using the Pentacam HR high-resolution rotating Scheimpflug camera (Oculus, Wetzlar, Germany). In one eye of each patient, the root-mean-square (RMS) of anterior, posterior, and total corneal spherical aberration Z4(0) was calculated by ray-tracing on an area of 6 mm diameter. The Pearson correlation coefficient (r) was used to assess correlations between Z4(0) RMS values and age/total corneal refractive power. The χ2 test was used to compare the proportion of eyes qualifying for spherically neutral or negatively aspheric (-0.17 and -0.27 μm) intraocular lenses (IOLs) by targeted level of residual spherical aberration.
Results: Fifty-seven men and 92 women were included (mean [±SD] age, 71.73 [±9.12] years). The RMS mean (±SD) values of Z4(0) were +0.353 (±0.132) μm, -0.121 (±0.034) μm, and +0.328 (±0.132) μm, respectively, for the anterior, posterior, and total cornea. The anterior, posterior, and total Z4(0) were on average significantly higher (p < 0.001) in women than in men. In both sexes, statistically significant (p < 0.05) age-related changes were found for the anterior and total Z4(0) but not for the posterior Z4(0) (p > 0.05). The total Z4(0) and total corneal refractive power were significantly correlated in men (p = 0.01) but not in women (p = 0.14). For postoperative targets of 0 ± 0.05/+0.10 ± 0.05 μm residual Z4(0), the proportion of eyes that would have qualified for implantation of negatively aspheric IOLs with -0.17 and with -0.27 μm was similar (61.1 and 56.3%, respectively; p = 0.09); significantly fewer eyes (6.7%) would have qualified for implantation of neutrally aspheric IOLs (p > 0.05).
Conclusions: Total corneal Z4(0) measured by Pentacam HR might be higher than that reported in previous studies. In most patients, the implantation of commercially available negatively aspheric IOLs would partially compensate for the positive total corneal Z4(0).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0000000000000380 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!