A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry. | LitMetric

Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry.

Phys Med Biol

Faculty of Health Sciences and Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney, Australia.

Published: October 2014

Attenuation correction in positron emission tomography brain imaging of freely moving animals is a very challenging problem since the torso of the animal is often within the field of view and introduces a non negligible attenuating factor that can degrade the quantitative accuracy of the reconstructed images. In the context of unrestrained small animal imaging, estimation of the attenuation correction factors without the need for a transmission scan is highly desirable. An attractive approach that avoids the need for a transmission scan involves the generation of the hull of the animal's head based on the reconstructed motion corrected emission images. However, this approach ignores the attenuation introduced by the animal's torso. In this work, we propose a virtual scanner geometry which moves in synchrony with the animal's head and discriminates between those events that traversed only the animal's head (and therefore can be accurately compensated for attenuation) and those that might have also traversed the animal's torso. For each recorded pose of the animal's head a new virtual scanner geometry is defined and therefore a new system matrix must be calculated leading to a time-varying system matrix. This new approach was evaluated on phantom data acquired on the microPET Focus 220 scanner using a custom-made phantom and step-wise motion. Results showed that when the animal's torso is within the FOV and not appropriately accounted for during attenuation correction it can lead to bias of up to 10% . Attenuation correction was more accurate when the virtual scanner was employed leading to improved quantitative estimates (bias < 2%), without the need to account for the attenuation introduced by the extraneous compartment. Although the proposed method requires increased computational resources, it can provide a reliable approach towards quantitatively accurate attenuation correction for freely moving animal studies.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/59/19/5651DOI Listing

Publication Analysis

Top Keywords

attenuation correction
20
virtual scanner
16
animal's head
16
scanner geometry
12
animal's torso
12
freely moving
8
small animal
8
transmission scan
8
traversed animal's
8
system matrix
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!