To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-014-9989-6DOI Listing

Publication Analysis

Top Keywords

accutome pachpen
8
ultrasonic pachymeter
8
reproducibility personnel
8
personnel training
8
training grades
8
intra-observer repeatability
8
repeatability inter-observer
8
inter-observer reproducibility
8
ophthalmic nurse
8
cct measured
8

Similar Publications

Ocular pulse amplitude (OPA) in canine -open-angle glaucoma (-OAG).

Front Bioeng Biotechnol

December 2023

Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, MI, United States.

The role of ocular rigidity and biomechanics remains incompletely understood in glaucoma, including assessing an individual's sensitivity to intraocular pressure (IOP). In this regard, the clinical assessment of ocular biomechanics represents an important need. The purpose of this study was to determine a possible relationship between the G661R missense mutation in the gene and the ocular pulse amplitude (OPA), the difference between diastolic and systolic intraocular pressure (IOP), in a well-established canine model of open-angle glaucoma (OAG).

View Article and Find Full Text PDF

Comparison of three rebound tonometers in normal and glaucomatous dogs.

Vet Ophthalmol

January 2023

Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, USA.

Objective: The objectives of the study were to compare intraocular pressure (IOP) readings across a wide range and obtained via three rebound tonometers in ADAMTS10-mutant Beagle-derived dogs with different stages of open-angle glaucoma (OAG) and normal control dogs and to investigate the effect of central corneal thickness (CCT).

Animals Studied: Measurements were performed on 99 eyes from 50 Beagle-derived dogs with variable genetics-16 non-glaucomatous and 34 with ADAMTS10-OAG. Seventeen OAG eyes were measured twice-with and without the use of IOP-lowering medications.

View Article and Find Full Text PDF

Purpose: To evaluate the agreement of central corneal thickness (CCT) measurement between Scheimpflug imaging and ultrasound (U/S) pachymetry in keratoconic eyes, and investigate factors that affect the agreement.

Methods: This post hoc analysis within a prospective, observational non-randomised study preformed at the Kensington Eye Institute, Toronto, Ontario, Canada, included crosslinking candidates with progressive keratoconus (KC). Main outcome measures were the agreement of CCT measurement between Scheimpflug imaging (Pentacam Oculus, Wetzlar, Germany) and U/S pachymetry (PachPen 24-5100, Accutome Inc.

View Article and Find Full Text PDF

Purpose: Corneal central thickness (CCT) is an important risk factor for glaucoma, which also influences intraocular pressure (IOP) measurements. Recently, all community optometrists in Scotland were provided with pachymeters. This study examined the accuracy of CCT measured by community optometrists compared to measurements in the glaucoma clinic.

View Article and Find Full Text PDF

To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2).