Intravenous contrast injection significantly affects bone mineral density measured on CT.

Eur Radiol

Department of Radiology and Internal Medicine-Geriatrics, University Medical Center Utrecht, Postbus 85500, Postbox: E.03.511, 3508, GA, Utrecht, Netherlands,

Published: February 2015

Objective: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications.

Methods: One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1).

Results: CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25% false negatives.

Conclusions: Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT.

Key Points: • Routine CT may gain a role in bone attenuation measurements for osteoporosis • Contrast media injection has substantial influence on CT-derived bone density • Contrast-enhanced CT leads to underestimation of osteoporosis compared to unenhanced CT • Adjusting for contrast injection phase may improve CT screening protocols for osteoporosis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-014-3408-2DOI Listing

Publication Analysis

Top Keywords

intravenous contrast
8
bone mineral
8
mineral density
8
unenhanced contrast-enhanced
8
ct-attenuation values
8
contrast injection
4
injection bone
4
density measured
4
measured objective
4
objective objective
4

Similar Publications

Objectives: To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

Materials And Methods: Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy.

View Article and Find Full Text PDF

Purpose: To explore the evaluation value of contrast enhanced ultrasound (CEUS) quantitative parameters in ischemic-type biliary lesions after liver transplantation to assist its early-diagnosis.

Methods: Patients who underwent liver transplantation and intravenous CEUS at Beijing Friendship Hospital, Capital Medical University from June 25, 2020 to December 28, 2022 and were diagnosed with Ischemic-type biliary lesions (ITBLs) by Magnetic Resonance Cholangiopancreatography (MRCP) or Endoscopic Retrograde Cholangiopancreatography (ERCP) or Percutaneous Transhepatic Cholangiography (PTC) were prospectively enrolled. SonoLiver software was used to quantitatively analyze the contrast images, transplanted livers with normal biliary tracts as the control group.

View Article and Find Full Text PDF

Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).

Methods: 148 patients (45 female, 65.1 ± 14.

View Article and Find Full Text PDF

To assess the utility of IVIM parameters in evaluating uterine fibroid blood flow compared to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) derived blood flow. Sixteen premenopausal women with uterine fibroids were enrolled in this prospective study. Pelvic MRI scans were obtained for each subject, both with and without continuous intravenous infusion of oxytocin, known to decrease significantly uterine fibroid blood flow, to assess the changes in blood flow of uterine fibroids.

View Article and Find Full Text PDF

Despite significant global reductions in cases of pneumonia during the last 3 decades, pneumonia remains the leading cause of post-neonatal mortality in children aged <5 years. Beyond the immediate disease burden it imposes, pneumonia contributes to long-term morbidity, including lung function deficits and bronchiectasis. Viruses are the most common cause of childhood pneumonia, but bacteria also play a crucial role.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!