Speed and low cost, together with regulatory approval, are the most important requirements of clinical assays. Therefore, a fast and automated on-line sample preparation method is essential for the routine analysis of biological samples. Microextraction by packed sorbent is an option for optimal sample preparation due to its easy automation, minimal requirements for the sample and elution solvent volumes, elimination of evaporation and reconstitution steps, and ability to integrate sample preparation and injection into one step. The use of effective sample preparation steps circumvents the need for chromatographic separation and therefore allows more rapid and less expensive sample analysis in clinical and forensic practice. Two biologically active compounds, amphetamine and methadone, were chosen as representative drugs of abuse for the application of microextraction by packed sorbent coupled directly to mass spectrometry. The developed method was validated, with the results confirming the suitability of the combination of these techniques for the analysis of biological samples. The approach was confirmed to be appropriate for use in clinical and forensic practice with regard to cost and time requirements for analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201400523DOI Listing

Publication Analysis

Top Keywords

sample preparation
16
microextraction packed
12
packed sorbent
12
clinical forensic
12
amphetamine methadone
8
sorbent coupled
8
coupled directly
8
directly mass
8
mass spectrometry
8
analysis biological
8

Similar Publications

This research highlights a sustainable approach for the design and synthesis of a magnetic nickel ferrite (NiFeO) catalyst reutilizing industrial waste, specifically iron ore tailing and Raney nickel catalyst processing waste, by simple co-precipitation method. Transforming waste materials into high-performance catalysts, this study aligns with the principles of a circular economy, addressing both environmental waste and pollution. Structural characterization by X-ray diffraction (XRD) and microscopic (FESEM and TEM) revealed the formation of well crystalline nano ferrite with NiFeO nanoparticles with cubic spinel structure.

View Article and Find Full Text PDF

Water-soluble and biocompatible protein carbon dots (P-CDs) were simply prepared from egg white by a rapid one-step neutralization heat reaction. Unexpectedly, the thus-fabricated P-CDs could present excitation-dependent tunable fluorescence that could be quenched specifically by Fe and Fe ions with obvious color changes. A high-throughput fluorimetric platform was thereby developed by coating the P-CDs onto a capillary array for detection of total iron ions in fish blood samples, with a linear concentration range of 0.

View Article and Find Full Text PDF

In the present research, an attempt has been made to develop a new thin film microextraction method for the extraction of several polycyclic aromatic hydrocarbons from aqueous samples collected from different industrial units prior to their analysis by gas chromatography combined with a flame ionization detector. In this approach, a thin iron mesh was modified by the formation of iron(II) oxinate on its surface and used for the extraction of analytes without an additional sorbent. For this purpose, first, the mesh was immersed in a sulfuric acid solution and then transferred into an 8-hydroxy quinoline (oxine) solution dissolved in ammonia solution.

View Article and Find Full Text PDF

Thermal- and Rate-Regulated Fast Switchable Adhesion within Glass Transition Zone of an Epoxy Polymer.

Langmuir

January 2025

Institute of Advanced Manufacturing Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Changzhou 213164, People's Republic of China.

Thermoresponsive shape memory polymer (SMP) adhesives have demonstrated a high adhesion strength and large switching ratios on different substrates. However, a long response time to switch adhesion on or off is generally encountered. This study provides a fast adhesion switching method based on the temperature and rate dependence of adhesion within the glass-transition zone of an epoxy polymer.

View Article and Find Full Text PDF

The most common method for detection of apoptosis is flow cytometry. In previously published studies there are some uncertainties and problems about the preparation of adherent cell lines for analysis. Thus, the aim of this study is to determine and describe how preparing the sample of SW-480 cells in two different ways affects the reliability of the results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!