Aims: In the setting of paroxysmal atrial fibrillation (AF), there are no available data comparing the mid-term outcome of patients undergoing pulmonary vein isolation (PVI) catheter ablation using contact-force (CF)-guided radiofrequency (RF) vs. second-generation balloon cryotherapy.

Methods And Results: Prospective single-centre evaluation, carried out from March 2011 to February 2013, comparing CF radiofrequency (Thermocool(®) SmartTouch™, Biosense Webster, Inc.) (CF group) with cryoballoon ablation (Arctic Front Advance™ 28 mm cryoballoon, Medtronic, Inc.) (CB group), in regards to procedural safety and efficacy, as well as recurrence at 12 months. Overall, 150 consecutive patients were enrolled (75 in each group). The characteristics of patients of both the groups were similar (61.2 ± 9.9 years, women 25.3%, mean AF duration 4.1 ± 4.0 years, mean CHA2DS2-VASc score 1.4 ± 1.3, mean HAS-BLED 1.4 ± 0.6). Duration of the procedure was significantly lower in the CF group (110.7 ± 32.5 vs. 134.5 ± 48.3 min, P = 0.001), with a lower duration of fluoroscopy (21.5 ± 8.5 vs. 25.3 ± 9.9 min, P = 0.017) and X-ray exposure (4748 ± 2411 cGy cm² vs. 7734 ± 5361 cGy cm², P = 0.001). In contrast, no significant difference was found regarding significant procedural complication (2.7 vs. 1.3% in CF and CB groups, respectively; P = 0.56), and PVI was eventually achieved in all cases. At 12 months, AF recurrence occurred in 11 patients (14.7%) in the CB group and in 9 patients (12.0%) in the CF group (HR = 1.20 95% CI 0.50-2.90; log rank P = 0.682).

Conclusions: Our preliminary findings suggest that CF-guided radiofrequency and cryotherapy present very similar performances in the setting of paroxysmal AF catheter ablation.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euu215DOI Listing

Publication Analysis

Top Keywords

radiofrequency second-generation
8
second-generation balloon
8
pulmonary vein
8
vein isolation
8
paroxysmal atrial
8
setting paroxysmal
8
catheter ablation
8
cf-guided radiofrequency
8
cgy cm²
8
patients
6

Similar Publications

Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study.

J Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK; Department of Cardiovascular Sciences, Clinical Science Wing, University of Leicester, Glenfield Hospital, Leicester, UK; National Institute for Health Research Leicester Research Biomedical Centre, Leicester, UK.

Background: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) can be performed using one-shot cryoballoon ablation (cryo) or point-by-point radiofrequency ablation (RF). This study compares the changes in P-wave parameters between both ablation methods.

Methods: This single-centre retrospective study included contact force RF and second-generation cryo for PAF between 2018 and 2019.

View Article and Find Full Text PDF

Background: There are no randomized studies comparing the maintenance of sinus rhythm after catheter ablation (CA) concerning treatment with antiarrhythmic drugs (AA) in elderly patients with paroxysmal atrial fibrillation (AF).

Objectives: To compare the clinical results of pulmonary vein (PV) isolation with the second-generation PVAC Gold catheter against AA treatment in elderly people with recurrent symptomatic paroxysmal AF, refractory to at least one AA, and without structural heart disease.

Methods: Sixty patients with paroxysmal AF ≥ 65 years old were randomized to two forms of treatment: group 1: CA and group 2: AA drugs.

View Article and Find Full Text PDF
Article Synopsis
  • A meta-analysis was conducted on ten randomized, sham-controlled trials involving 2,478 patients with hypertension to evaluate the efficacy and safety of catheter-based renal denervation (RDN) using first- and second-generation devices.
  • The results showed that RDN significantly lowered both 24-hour and office systolic and diastolic blood pressure compared to a sham procedure, with reductions of up to 6.6 mmHg for systolic BP.
  • Safety outcomes revealed no significant differences in adverse events, including vascular complications and renal function changes, between the RDN and sham groups, indicating that RDN is both effective and safe.
View Article and Find Full Text PDF

Background: Hyperuricemia (HU) has been reported to be associated with a high incidence of atrial fibrillation (AF). However, the relationship between HUA and recurrent AF after catheter ablation (CA) is unclear.

Methods: Four hundred consecutive AF patients (paroxysmal/persistent AF [PAF/PsAF]: 200/200) who underwent the initial CA were retrospectively enrolled.

View Article and Find Full Text PDF

Background: The cryoballoon (CB) has become a standard tool for pulmonary vein isolation (PVI), but the technology is limited in certain ways. A novel RF-balloon (Heliostar™, Biosense Webster, CA, USA) promises the advantages of a balloon technology in combination with 3D mapping.

Methods: To assess procedural data and outcome, all patients undergoing RF-balloon PVI were included and compared with data from consecutive patients undergoing CB PVI for paroxysmal AF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!