Objective: To assess whether the need for postnatal prosthetic patch repair of the diaphragmatic defect in neonates with a congenital diaphragmatic hernia (CDH) is associated with the antenatal measured observed-to-expected magnetic resonance fetal lung volume (o/e MR-FLV).
Methods: The o/e MR-FLV was calculated in 247 fetuses with isolated CDH. Logistic regression analysis was used to assess the prognostic value of the individual o/e MR-FLV for association with the need for postnatal patch repair.
Results: Seventy-seven percent (77%) of patients with a CDH (190/247) required prosthetic patch repair and the defect was closed primarily in 23% (57/247). Patients requiring a patch had a significantly lower o/e MR-FLV (27.7 ± 10.2%) than patients with primary repair (40.8 ± 13.8%, p < 0.001, AUC = 0.786). With an o/e MR-FLV of 20%, 92% of the patients required patch repair, compared to only 24% with an o/e MR-FLV of 60%. The need for a prosthetic patch was further influenced by the fetal liver position (herniation/no herniation) as determined by magnetic resonance imaging (MRI; p < 0.001). Fetal liver position, in addition to the o/e MR-FLV, improves prognostic accuracy (AUC = 0.827).
Conclusion: Logistic regression analysis based on the o/e MR-FLV is useful for prenatal estimation of the prosthetic patch requirement in patients with a CDH. In addition to the o/e MR-FLV, the position of the liver as determined by fetal MRI helps improve prognostic accuracy.
Key Points: • The o/e MR-FLV is associated with the need for postnatal patch repair in CDH. • The need for a patch is associated with a significantly lower o/e MR-FLV (p < 0.001). • The patch requirement is also influenced by fetal liver position. • Fetal liver position, in addition to the o/e MR-FLV, improves prognostic accuracy. • CDH-fetuses with a high probability for patch requirement can be identified prenatally.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-014-3410-8 | DOI Listing |
Eur Radiol
January 2015
Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany,
Objective: To assess whether the need for postnatal prosthetic patch repair of the diaphragmatic defect in neonates with a congenital diaphragmatic hernia (CDH) is associated with the antenatal measured observed-to-expected magnetic resonance fetal lung volume (o/e MR-FLV).
Methods: The o/e MR-FLV was calculated in 247 fetuses with isolated CDH. Logistic regression analysis was used to assess the prognostic value of the individual o/e MR-FLV for association with the need for postnatal patch repair.
Eur Radiol
February 2014
Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany,
Objective: To investigate individual changes in fetal lung volume (FLV) in fetuses with isolated congenital diaphragmatic hernia (CDH) and to calculate weekly growth rates of the FLV using serial MR examinations during pregnancy.
Methods: MR-FLV was measured in 89 fetuses with CDH. All fetuses received two MRIs.