AI Article Synopsis

  • The study aimed to assess the accuracy of dental implant placement in patients with severe maxilla bone loss using advanced computer planning and surgical templates.
  • A total of 150 implants were placed in 25 patients, revealing average deviations of about 1.5 mm in depth and 2.5° in angulation, with 53% being placed too superficially compared to initial plans.
  • The findings highlight that while computer-aided planning can be beneficial, surgeons must remain cautious of potential deviations during the procedure.

Article Abstract

Purpose: The purpose of this study was to determine the clinically relevant accuracy of implant placement in the augmented maxilla using computer planning and a mucosa-supported surgical template.

Materials And Methods: Twenty-five consecutive edentulous patients with an extreme maxillar alveolar ridge resorption were treated with a bone augmentation procedure. In a second stage, six Brånemark MkIII Groovy (Nobel Biocare®, Zürich, Switzerland) implants were installed. Preoperatively, a cone beam computer tomography (CBCT) scan was acquired, followed by virtual implant planning and flapless implant placement using a surgical template. A postoperative CBCT scan was acquired and registered to the preoperative scan. The Implant Position Orthogonal Projection validation method was applied to measure implant deviations in both the buccolingual and mesio-distal plane. The influence of fixation pins and the position on the dental arch were investigated with regard to implant deviations, and rotations and translations of the surgical template.

Results: One hundred fifty implants were installed. In mesio-distal direction, a mean implant deviation of 1.50 mm was scored at the implant tip, 1.27 mm at the shoulder, -0.60 mm in depth, as well as a mean deviation of angulation of 2.50°. In buccolingual direction, a mean implant deviation of 0.99 mm was found at the implant tip, 0.76 mm at the implant shoulder, -0.57 mm in depth, and a deviation of angulation of 2.48°. Of all implants, 53% was placed too superficial compared with the planning. The use of fixation pins and implant deviations in both buccal and mesial directions as also for rotations and translation of the surgical template showed statistically significant differences.

Conclusions: Computer-aided implant planning showed to be a clinically relevant tool. However, this study emphasizes that the surgeon should take into account that deviations are larger compared with implant placement without augmentation procedure. Deviations are mainly caused by angulations and translations of the surgical template.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cid.12230DOI Listing

Publication Analysis

Top Keywords

implant placement
16
implant
15
surgical template
12
implant deviations
12
placement augmented
8
augmented maxilla
8
mucosa-supported surgical
8
clinically relevant
8
augmentation procedure
8
implants installed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!