Introduction: Rotating-hinge knee implants are highly constrained devices able to provide the stability needed for arthroplasty in case of severe bone loss and complex instability. Notable doubts still exist in using rotating-hinge devices, mainly due to risk of mechanical failure and risk of infection.

Materials And Methods: We retrospectively evaluated the functional and clinical outcomes in a series of patients treated with the rotating-hinge Endo-Model prosthesis either for primary or revision total knee arthroplasty. Between 1997 and 2009 we implanted 123 Endo-Model prosthesis (118 patients) at our institution. At the time of this study we could evaluate 45 prosthesis (25 primary and 20 revision TKAs) from the clinical and radiological site, with average follow-up of 42.2 months.

Results: During the follow-up period, three patients reported complications, which in two cases finally led to revision with explantation. Mean survival of the implants attested at 93.3 %. The average post-operative clinical Knee Society score in the evaluated series was 94.2, the functional one 78.7. The average range of motion was 0°-108°. No signs of joint instability or misalignment were noted. Pain was present in a minority of patients, but always at a mild/occasional extent. No evidences of loosening or implant failure have been reported. No substantial divergences in the outcomes have been found across different patient categories after stratification in agreement with the Knee Society.

Conclusions: Coherent with previously published works, we confirm the Endo-Model prosthesis to provide excellent pain relief, restoration of walking capacity and intrinsic knee stability both in complex primary and in revision knee arthroplasty, with good or excellent results in the majority of patients and acceptable complication rate.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-014-2061-1DOI Listing

Publication Analysis

Top Keywords

endo-model prosthesis
16
primary revision
16
knee arthroplasty
12
total knee
8
rotating-hinge endo-model
8
complex primary
8
prosthesis primary
8
knee
6
prosthesis
5
revision
5

Similar Publications

Introduction: Hinge knee joint prosthesis are utilized in a variety of surgical scenarios, including complex primary, revision, salvage surgeries, and radical resection of tumor's. Link's Endo-model Hinged Knee Prosthesis is a newer design that includes ramped tibial components for controlled pivot point motion during flexion and an anti-dislocation feature to prevent prosthesis dislocation..

View Article and Find Full Text PDF

Purpose: Treatment of secondary knee osteoarthritis with a significant extra-articular deformity can be challenging. In such cases, an osteotomy or a custom-made hinged knee arthroplasy (CMH) are treatment options. However, there are limited data on the outcomes of using CMHs.

View Article and Find Full Text PDF

Background And Objective: Adequate fixation is a requisite for hinged Total Knee Arthroplasty (TKA): consequently, several stem solutions are currently available. However, there are no evidence-based biomechanical guidelines for surgeons to determine the appropriate stem length and whether to use cemented or press-fit fixation. The objective of this study is therefore to compare, using a validated finite-element model, bone stresses and implant micromotions in different configurations.

View Article and Find Full Text PDF

The survivorship of the link endo-rotational hinge total knee arthroplasty: 5-12-year follow-up of 100 patients.

Arch Orthop Trauma Surg

January 2019

Department of Orthopaedic Surgery, Royal Infirmary of Edinburgh, 51 Little France Crescent, Edinburgh, EH16 4SA, Scotland, UK.

Introduction: There is a paucity of survival data reporting the medium to long-term outcome of the LINK® Endo-Model rotational hinge total knee arthroplasty (ERH-TKA). Such information is essential when counselling patients and predictors of survival would help inform patients of their likely outcome.

Materials And Methods: A series of patients, who received an ERH-TKA, with a minimum follow-up of 5 years, were retrospectively identified from an established arthroplasty database.

View Article and Find Full Text PDF

Objective: To present the indications, technical aspects, and initial results of the first cases using Endo-Model™ implants in Brazil.

Methods: A prospective study was conducted. It included nine patients submitted to a total knee arthroplasty, of which six were primary and three were revisions, using exclusively the Endo-Model™ implant.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!