The PowerPlex(®) ESI 16 Fast, ESI 17 Fast, ESX 16 Fast, and ESX 17 Fast Systems represent faster cycling versions (50min or less) of the PowerPlex(®) ESI and ESX Systems released by Promega in 2009 to accommodate the ENFSI and EDNAP groups' call for new STR multiplexes for Europe. In addition to amplification of purified DNA samples, these new faster cycling systems allow for direct amplification from single-source blood and buccal samples deposited on FTA(®) and nonFTA paper as well as from SwabSolution™ extracts of buccal swabs without the need for purification and quantitation. There are no changes to the autosomal primer pair sequences in the PowerPlex(®) ESI Fast and ESX Fast Systems compared to the original multiplexes, and full concordance at all autosomal loci and amelogenin was observed with data generated previously with the original PowerPlex(®) ESI and ESX Systems. This paper describes the developmental validation study performed on these new fast systems following guidelines issued by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and those of the DNA Advisory Board (DAB). Validation data demonstrate that these systems are sensitive for detecting low levels of DNA while also being capable of generating robust profiles from the high amount of input DNA present in direct-amplification samples. These systems are also tolerant to both high concentrations of PCR inhibitors as well as to slight variations in the final concentration of master mix and primer pair present in the amplification reaction that might be encountered due to pipetting error. The results of this validation study demonstrate that these systems may be used on multiple thermal cyclers and capillary electrophoresis platforms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.fsigen.2014.08.004 | DOI Listing |
J Agric Food Chem
January 2025
Laboratory of Bioactives (LABBIO), Food and Nutrition Graduate Program (PPGAN), Federal University of the State of Rio de Janeiro (UNIRIO), Rio de Janeiro 22290-240, Brazil.
Phenolic compounds (PC) were analyzed by UHPLC-ESI-QTOF-MS in two sorghum genotypes, harvested in two growing seasons (GS) at five distinct days after flowering (DAF) to evaluate how genotype/GS influences the PC synthesis and antioxidant capacity during grain growth. Total phenolic contents were strongly correlated with antioxidant capacity ( > 0.9, < 0.
View Article and Find Full Text PDFPhytochem Anal
January 2025
School of Pharmacy, Shaanxi University of Chinese Medicine, Xianyang, China.
Introduction: Farfarae Flos is widely used as a traditional herbal medicine. Currently, its size has been the primary grading criterion used in market circulation. Whether this empirical criterion can accurately reflect the quality of the medicinal material has not been systematically studied.
View Article and Find Full Text PDFFood Chem
January 2025
Department of Food Technology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil. Electronic address:
This study aimed to identify an efficient and sustainable extraction method for phenolic compounds and flavonoids from I. laurina using maceration (conventional), ultrasonic bath and probes, cup horn sonication, and microwave. It evaluated extraction parameters and assessed total phenolic compounds, flavonoids, antioxidant, and antimicrobial capacities, with annotated compounds via ESI-ToF-MS and the green analytical procedure index analysis.
View Article and Find Full Text PDFJ Chromatogr A
January 2025
School of Pharmacy, Shenyang Pharmaceutical University, Shenyang 110016, PR China. Electronic address:
Evodiamine, a chiral quinazoline alkaloid in the traditional Chinese medicine Evodiae fructus, exhibited efficacy for CNS diseases. In this study, the pure enantiomers of evodiamine were prepared in large quantities via chemical resolution. Their structures were elucidated by MS, NMR and ECD.
View Article and Find Full Text PDFEnviron Sci Process Impacts
January 2025
Massachusetts Institute of Technology, Department of Civil and Environmental Engineering, Parsons Laboratory, 15 Vassar Street, Cambridge, Massachusetts 02139, USA.
The high salinity and organic content in oil and gas wastewaters can cause ion suppression during liquid chromatography mass spectrometry (LC/MS) analysis, diminishing the sensitivity and accuracy of measurements in available methods. This suppression is severe for low molecular weight organic compounds such as ethanolamines (, monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), -methyldiethanolamine (MDEA), and ,-ethyldiethanolamine (EDEA)). Here, we deployed solid phase extraction (SPE), mixed-mode LC, triple quadrupole MS with positive electrospray ionization (ESI), and a suite of stable isotope standards (, one per target compound) to correct for ion suppression by salts and organic matter, SPE losses, and instrument variability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!