A young child with bilateral diaphragmatic palsy after bilateral bidirectional Glenn shunt.

Mymensingh Med J

Dr AK Shamsuddin, Associate Professor & Senior Consultant, Pediatric Cardiac Surgery, National Heart Foundation Hospital and Research Institute (NHFH & RI), Sher-E-Bangladesh, Bangladesh.

Published: July 2014

A 13-months old boy was admitted in National Heart Foundation Hospital and Research Institute on 3 August 2011 with the diagnosis of Dextrocardia, A-V discordance, DORV, large perimembranous VSD, severe infundibular and valvular PS, bilateral SVC. He was operated on 10 August 2011. Bilateral bidirectional Glenn shunt was done off pump along with interruption of PDA. Antegrade pulmonary blood flow was minimized by tight PA banding. Baby was extubated 3 hours after surgery but had to reintubate immediately due to intense respiratory distress. Subsequent three trials of extubation failed. Chest x-ray revealed elevation of both the hemidiaphragm. Ultrasonogram of abdomen and Bronchogram along with fluoroscopy done and bilateral diaphragmatic palsy was diagnosed. Tracheostomy was done on 25th August 2011. Plication of left hemidiaphragm was done on 27th August and right hemidiaphragm plication was done on 10th September 2011. Though it took long period of time we managed to take him out of ventilator on 57th postoperative day. He was oxygen dependent for a period of time and finally he managed to take his own breath without tracheostomy tube from 67th postoperative day. After a long eventful postoperative hospital stay he was discharged home on 78th postoperative day. Discharge Chest x-ray revealed well expanded lung with flattened diaphragm. Echo revealed well functioning bilateral Glenn shunt. Tracheostomy wound healed nicely and there was no evidence of tracheal stenosis.

Download full-text PDF

Source

Publication Analysis

Top Keywords

glenn shunt
12
august 2011
12
postoperative day
12
bilateral diaphragmatic
8
diaphragmatic palsy
8
bilateral bidirectional
8
bidirectional glenn
8
chest x-ray
8
x-ray revealed
8
period time
8

Similar Publications

Background: While several studies have explored the outcomes of transcatheter interventions for modified Blalock-Taussig shunts (MBTSs) in a broad range of congenital heart diseases, none have specifically examined the interventions in patients with hypoplastic left heart syndrome (HLHS) who underwent Norwood palliation (NP).

Methods: This retrospective study was conducted between 2020 and 2024, when 24 urgent interventions were performed on 17 patients at our center. We recorded several key outcomes, including early and late intervention-related complications, the need for reintervention, the interval between the NP and the first intervention, shunt patency following the intervention, associated morbidities, and thrombosis-related sudden events.

View Article and Find Full Text PDF

Glenn circulation causes early and progressive shunting in a surgical model of pulmonary arteriovenous malformations.

Physiol Rep

November 2024

Department of Pediatrics, Division of Cardiology, Medical College of Wisconsin, Children's Wisconsin, Herma Heart Institute, Milwaukee, Wisconsin, USA.

Pulmonary arteriovenous malformations (PAVMs) universally develop in patients with single ventricle congenital heart disease. Single ventricle PAVMs have been recognized for over 50 years but remain poorly understood. To improve our understanding, we developed a surgical rat model of Glenn circulation and characterized PAVM physiology over multiple time points.

View Article and Find Full Text PDF

Partial cavopulmonary shunt is an established procedure for patients with abnormal right ventricular (RV) physiology. Late failure of the Glenn shunt is usually due to further progression of the primary disease process. However, there may be surprises, as in our patient.

View Article and Find Full Text PDF

Undetected respiratory infections may adversely affect the intrapulmonary resistance after Stage 2 or Stage 3 Fontan palliation. A few studies describe a higher risk for viral pneumonia during respiratory virus season, but none of them have focused on the effect of symptomatic viral pneumonia on in-hospital clinical course after bidirectional Glenn shunt. We analysed 77 patients who underwent bidirectional Glenn shunt surgery.

View Article and Find Full Text PDF

Dual-chamber leadless pacemaker in complex adult congenital heart disease: a case report.

Eur Heart J Case Rep

October 2024

Department of Cardiac Electrophyioslogy, Royal Brompton and Harefield Hospitals, Guys and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK.

Article Synopsis
  • - Atrioventricular block is a common issue in adults with congenital heart disease, making pacemaker implantation difficult, thus highlighting the importance of atrioventricular synchronous pacing for improved blood flow.
  • - A 25-year-old male with a history of complex heart surgeries experienced heart block and had a malfunctioning pacemaker before receiving a dual-chamber leadless pacemaker, which successfully restored his heart's rhythmic function.
  • - This case represents a valuable addition to the management options for patients with complex congenital heart diseases, showcasing the effectiveness of leadless pacemakers in ensuring atrioventricular synchrony.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!