Objective: No clinically effective treatment for promoting peripheral axonal regeneration has yet been established. Several experimental studies in vitro and in vivo have shown that a high dose of methylcobalamin (MeCbl), an analogue of vitamin B12, promotes axonal growth in peripheral nerve injury. We herein assessed the safety and efficacy of an ultra-high dose MeCbl treatment for patients with peripheral neuropathy and chronic axonal degeneration.

Methods: Fourteen patients with immune-mediated or hereditary neuropathy in the chronic progressive or stable phase were enrolled. MeCbl, 25 mg/day for 10 days followed by monthly 25 mg for 5 months, was intravenously administered. The patients were evaluated before and 1 year following treatment. The primary endpoints were safety and improvement in the Medical Research Council (MRC) sum score in at least two muscles of the 20 muscles. This trial is registered with the University Hospital Medical Information Network (UMIN) Center in Japan under the ID: UMIN000009359.

Results: There were no adverse effects in twelve of the patients, whereas treatment was discontinued in two patients who had seborrheic dermatitis at 3 months and respiratory tract infection at 2 months, respectively. Therefore, twelve patients were evaluated for the primary outcomes; the MRC sum score was improved in seven of the patients and unchanged or worsened in the remaining five patients.

Conclusion: Intravenous ultra-high dose MeCbl treatment is a safe and potentially efficacious therapy for patients with peripheral neuropathy and chronic axonal degeneration.

Download full-text PDF

Source
http://dx.doi.org/10.2169/internalmedicine.53.1951DOI Listing

Publication Analysis

Top Keywords

ultra-high dose
12
peripheral neuropathy
12
neuropathy chronic
12
safety efficacy
8
intravenous ultra-high
8
dose methylcobalamin
8
dose mecbl
8
mecbl treatment
8
patients
8
patients peripheral
8

Similar Publications

[Therapeutic effect and mechanism of Jingfang Granules on chronic fatigue syndrome based on intestinal flora and metabolomics].

Zhongguo Zhong Yao Za Zhi

December 2024

School of Pharmacy, Shandong University of Traditional Chinese Medicine Ji'nan 250355, China State Key Laboratory of Integration and Innovation of Classic Formula and Modern Chinese Medicine, Lunan Pharmaceutical Group Co., Ltd. Linyi 276005, China.

This study aims to investigate the protective effect and potential mechanism of Jingfang Granules(JF) on the mouse model of chronic fatigue syndrome(CFS). Mice were randomized into normal, model, and low-, medium-, and high-dose(0.9, 1.

View Article and Find Full Text PDF

The current trend in food innovations includes developing products containing plant ingredients or extracts rich in bioactive compounds. This study aimed to prepare and characterize skimmed thermally treated goat's milk powders enriched with lyophilized fruit extracts of Murray (GMLR) and L. (GMLB).

View Article and Find Full Text PDF

Ultra-high dose-rate (FLASH) radiotherapy serves as an ideal procedure to treat tumors efficiently without harming normal tissues and has demonstrated satisfactory antitumor effects in multiple animal tumor models. However, the biological mechanisms of FLASH radiotherapy have not yet been fully elucidated, and the small number of devices delivering FLASH dose rate has limited its wide application. This review summarizes the possible biological mechanisms and antitumor effects of FLASH radiotherapy, its application in nanotherapeutic strategy, as well as its challenges and future development.

View Article and Find Full Text PDF

The advent of ultra-high dose rate irradiation, known as FLASH radiation therapy, has shown promising potential in reducing toxicity while maintaining tumor control. However, the clinical translation of these benefits necessitates efficient treatment planning strategies. This study introduces a novel approach to optimize proton therapy for FLASH effects using traveling salesperson problem (TSP) heuristics.

View Article and Find Full Text PDF

(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!