A survey of Iranian waters, sampled from 2010 to 2013, is presented. A total of 128 water samples from 42 different brands of bottled mineral and drinking water were collected and analysed for contamination levels of lead (Pb), cadmium (Cd), copper (Cu), arsenic (As) and mercury (Hg). Determinations were performed using a graphite furnace atomic absorption spectrophotometer for Pb, Cd and Cu, a hydride vapour generation as well as an Arsenator digital kit (Wagtech WTD, Tyne and Wear, UK) for As and a direct mercury analyser for Hg. Arsenic concentration in six bottled gaseous mineral samples was higher than the related limit. Regardless of these, mean concentrations of Pb, Cd, Cu, As and Hg in all types of water samples were 4.50 ± 0.49, 1.08 ± 0.09, 16.11 ± 2.77, 5.80 ± 1.63 and 0.52 ± 0.03 µg L⁻¹, respectively. Values obtained for analysed heavy metals in all samples were permissible according to the limits of national and international standards.