Objectives: The purpose of this study was to assess the need of bone graft or bone substitutes in unstable distal radius fractures (DRF) treated with locking compression plates (LCP) PATIENTS AND METHODS: An observational and prospective study was conducted on 60 patients with DRF AO-type A3 and AO-type C3, treated surgically by LCP plates without bone grafts or substitutes. Ranges of motion in flexion (F), extension (E), pronation (P), and supination (S) were measured in the injured wrist and compared with the healthy contralateral wrist. X-ray parameters: palmar tilt (PT), radial inclination (RI), ulnar variance (UV), and radial height (RH) were calculated in the injured wrist one year after surgery and then compared, with those parameters in the healthy contralateral wrist and in the follow-up postoperative x-ray of the injured wrist. PRWE and DASH scores were used to evaluate patient satisfaction.

Results: The range of motion loss was F 12° ± 16.1°, E 9° ± 13.1°, P 2.5° ± 7.5°, and S 5°±10°, but they remained within functional parameters. Good results were also obtained in the PRWE and DASH scores (DASH 12.6 ± 14.16 and PRWE 9.5 ± 9.5). All the fractures were healed without significant collapse (IP 0.55 ± 1.7°, IR 0.31 ± 1.5°, VC 0.25±0.8mm, and AR 0.1 ± 0.9 mm).

Conclusions: All fractures healed without problems or with significant loss of reduction. Bone graft and bone substitutes are not mandatory for treatment of unstable DRF with LCP plates. Their use increases the cost and is not exempt of morbidities. This study also reinforces the role of LCP plates in surgical treatment of unstable DRF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.recot.2014.07.009DOI Listing

Publication Analysis

Top Keywords

lcp plates
12
injured wrist
12
distal radius
8
radius fractures
8
bone grafts
8
bone graft
8
graft bone
8
bone substitutes
8
healthy contralateral
8
contralateral wrist
8

Similar Publications

Background: Low-profile double plating seems a viable alternative to conventional single plating for fixation of midshaft clavicle fractures. This study aims to compare the two techniques regarding healing, complications, and removal rate.

Methods: This retrospective cohort study included all patients >16 years that underwent plate fixation for midshaft clavicle fractures between 2020 and 2022 at one trauma-center.

View Article and Find Full Text PDF

Objective:  To determine the effect of locking head inserts (LHI) on plate strain, stiffness, and deformation when applied to a 3.5-mm broad locking compression plate (LCP) in an open fracture-gap model.

Study Design:  Six, 13-hole, 3.

View Article and Find Full Text PDF

Background: Length unstable femoral shaft fractures in school-aged children usually demand surgical treatment, but the optimal choice remains controversial, especially in overweight adolescents. This study aimed to compare the clinical results of locking compression plates (LCP) and elastic stable intramedullary nails (ESIN) combined with temporary external fixator (TEF) in school-aged children weighing over 50 kg.

Methods: Between January 2010 and January 2018, children over 50 kg with length unstable femoral shaft fracture treated with ESIN & EF in the authors' institute were included in this study.

View Article and Find Full Text PDF

Introduction: Posterior cruciate ligament (PCL) avulsion fractures of the tibia with ipsilateral tibial shaft represent a rare but challenging orthopedic injury, necessitating careful consideration of surgical interventions for optimal outcomes. This case report presents the successful management of tibial shaft fracture (proximal 1/3rd junction) along with ipsilateral PCL avulsion fracture of tibia using a novel approach using open reduction internal fixation (ORIF) of tibial shaft with Locking compression plate (LCP) with cannulated cancellous screw and spiked washer fixation of PCL avulsion. There are no case reports or research articles available for the management of PCL avulsion fracture of tibia associated with ipsilateral tibial shaft fracture.

View Article and Find Full Text PDF

Background: Severe metaphyseal comminution and sizable bone defect of the distal femur are high risks of fixation failure. To date, no exact magnitude of comminution and bone loss is determined as an indication for augmentation of fixation construct. The present study aimed to investigate the influence of metaphyseal gap width, working length, and screw distribution on the stability of the fixation construct.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!