A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of rivaroxaban and dabigatran levels in human plasma by high-performance liquid chromatography-tandem mass spectrometry. | LitMetric

AI Article Synopsis

  • A new liquid chromatography method combined with mass spectrometry has been created to accurately measure the levels of the blood thinners dabigatran and rivaroxaban.
  • The method utilized stable isotope-labeled standards for precise quantification and involved a straightforward protein precipitation step for preparing plasma samples.
  • Validation showed the method is reliable across various parameters, including sensitivity with a lower limit of quantification set at 2.5ng/mL for both medications.

Article Abstract

A sensitive and accurate liquid chromatography method with mass spectrometry detection was developed and validated for the quantification of dabigatran (Pradaxa(®)) and rivaroxaban (Xarelto(®)). (13)C6-dabigatran and (13)C6-rivaroxaban were used as the internal standard. A single-step protein precipitation was used for plasma sample preparation. This method was validated with respect to linearity, selectivity, inter- and intra-day precision and accuracy, limit of quantification and stability. The lower limit of quantification was 2.5ng/mL for both drugs in plasma.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2014.08.011DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
8
limit quantification
8
simultaneous determination
4
determination rivaroxaban
4
rivaroxaban dabigatran
4
dabigatran levels
4
levels human
4
human plasma
4
plasma high-performance
4
high-performance liquid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!