A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CAIPIRINHA-Dixon-TWIST (CDT)-volume-interpolated breath-hold examination (VIBE) for dynamic liver imaging: comparison of gadoterate meglumine, gadobutrol and gadoxetic acid. | LitMetric

Purpose: CAIPIRINHA-Dixon-TWIST (CDT)-VIBE is a robust method for abdominal magnetic resonance imaging providing both high spatial and high temporal resolution. The purpose of this study was to examine the influence of different gadolinium based contrast agents (GBCA) on image quality (IQ) with CDT-VIBE.

Materials And Methods: In this IRB-approved, retrospective, inter-individual comparison study, 86 patients scanned at 3T were included. Within 28s, 14 high-resolution 3D datasets were acquired using CDT-VIBE. 37 patients received 0.1mmol/kg gadoterate meglumine, 28 patients 0.1mmol/kg gadobutrol, and 19 patients 0.1mL/kg gadoxetic acid. Two blinded, board-certified radiologists assessed the image quality on a 5 point scale, as well as the number of hepatic arterial dominant (HAD) phases.

Results: Regardless of the GBCA utilized, CDT-VIBE resulted in good IQ in terms of best IQ achieved among all 14 datasets (gadobutrol 4.3, gadoterate meglumine 3.9, gadoxetic acid 3.7). With respect to worst IQ, the three groups showed statistically significant differences with gadobutrol receiving the highest rating (3.6) and gadoxetic acid the lowest (2.4) (gadoterate meglumine 3.0; 0.0014
Conclusion: Different gadolinium-based contrast agents can be utilized for dynamic liver imaging with CDT-VIBE resulting in good image quality.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2014.08.003DOI Listing

Publication Analysis

Top Keywords

gadoterate meglumine
16
gadoxetic acid
16
image quality
8
caipirinha-dixon-twist cdt-volume-interpolated
4
cdt-volume-interpolated breath-hold
4
breath-hold examination
4
examination vibe
4
vibe dynamic
4
dynamic liver
4
liver imaging
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!