A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of CTX-II in serum and urine to diagnose osteoarthritis by using a fluoro-microbeads guiding chip. | LitMetric

Detection of CTX-II in serum and urine to diagnose osteoarthritis by using a fluoro-microbeads guiding chip.

Biosens Bioelectron

Department of Molecular Science and Technology, Ajou University, Suwon 443749, South Korea. Electronic address:

Published: May 2015

This study reports a new strategy for simultaneous detection of the C-telopeptide fragments of type II collagen (CTX-II) as a biomarker of osteoarthritis (OA) using a fluoro-microbeads guiding chip. As osteoarthritis progresses, the joint components including matrix and cartilage are degraded by proteases. The degraded products such as CTX-II are released into the serum and urine, and the CTX-II concentration in body fluids reflects OA progression. Because the CTX-II has heterogeneous epitope structure in serum (sCTX-II; homodimers) and urine (uCTX-II; monomers or variant monomers), a multiple-sensing device enabling both sandwich and competitive-type immunoassays is required. For multiple assessments of serum and urinary CTX-II, we designed a fluoro-microbeads guiding chip (FMGC) containing multiple sensing areas and connecting channels. Using the approach, the sandwich (sCTX-II) and competition (uCTX-II) assays could be simultaneously performed on a single chip. We designed a fluidic control device enabling selective control of the open-close function of FMGC channels. The immune-specific signal was quantitatively analyzed by counting the number of fluorescent microbeads from the registered images. The results from the developed FMGC assay showed high correlation with those obtained in ELISA. The completion time of the FMGC assay was 24-fold and 3.5-fold shorter than the ELISA for urinary and serum CTX-II. Taken together, it enabled the simultaneous detection of both sCTX-II and uCTX-II. This FMGC-based assay would be a promising tool for monitoring of osteoarthritis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2014.08.016DOI Listing

Publication Analysis

Top Keywords

fluoro-microbeads guiding
12
guiding chip
12
serum urine
8
osteoarthritis fluoro-microbeads
8
simultaneous detection
8
device enabling
8
fmgc assay
8
ctx-ii
6
serum
5
detection ctx-ii
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!