This case report describes a successful implant-prosthetic rehabilitation of an atrophic posterior mandible with 4-mm-long implants. The patient refused to undergo any reconstructive surgery, and because the available bone up to the inferior alveolar nerve was only 5 mm or less, the patient received four implants of 4-mm length. Four months after implant placement, a provisional prosthesis was put in place; after another 4 months, this was then in turn replaced with a definitive prosthesis. The use of such short implants allows a fixed prosthetic solution without the need for vertically augmenting the mandibular bone. This procedure considerably reduces intra- and postoperative patient discomfort compared with reconstructive surgery for the placement of longer implants. The follow-up time was 1 year after implant loading.

Download full-text PDF

Source
http://dx.doi.org/10.11607/prd.1733DOI Listing

Publication Analysis

Top Keywords

rehabilitation atrophic
8
atrophic posterior
8
posterior mandible
8
case report
8
reconstructive surgery
8
implants
5
mandible short
4
short 4-mm
4
4-mm implants
4
implants case
4

Similar Publications

Displacement MMG-based estimation of dynamic muscle viscoelasticity in the quadriceps during passive pedaling.

Sci Rep

January 2025

Graduate School of Interdisciplinary Science and Engineering of Health Systems, Okayama University, Okayama, 700-0082, Japan.

We explore the correlation between muscle viscoelasticity and displacement mechanomyography (DMMG) during passive joint movement. Current methods for assessing muscle viscoelasticity (which is essential for rehabilitation and sports conditioning) are limited in terms of simplicity, objectivity, and portability. We introduce a novel methodology employing DMMG during passive pedaling to evaluate these properties.

View Article and Find Full Text PDF

Skeletal organoids.

Biomater Transl

November 2024

Organoid Research Center, Institute of Translational Medicine, Shanghai University, Shanghai, China.

The skeletal system, composed of bones, muscles, joints, ligaments, and tendons, serves as the foundation for maintaining human posture, mobility, and overall biomechanical functionality. However, with ageing, chronic overuse, and acute injuries, conditions such as osteoarthritis, intervertebral disc degeneration, muscle atrophy, and ligament or tendon tears have become increasingly prevalent and pose serious clinical challenges. These disorders not only result in pain, functional loss, and a marked reduction in patients' quality of life but also impose substantial social and economic burdens.

View Article and Find Full Text PDF

Background: Tooth agenesis, particularly the absence of upper lateral incisors, presents substantial challenges for clinicians due to the associated bone atrophy, which limits the use of traditional implant solutions. Current options, such as endosseous implants combined with guided bone regeneration (GBR), often fail due to insufficient osseointegration in atrophic bone. This study aims to evaluate the effectiveness of custom-made, additively manufactured subperiosteal implants in addressing these challenges METHODS: This retrospective study assessed 16 custom-made subperiosteal implants used in 12 patients (10 females, 2 males; mean age 25 ± 2.

View Article and Find Full Text PDF

Purpose The infrapatellar fat pad (IFP) has the lowest pain threshold among all knee joint components and causes anterior knee pain after knee arthroplasty. It has been reported that selective muscle atrophy of the vastus medialis (VM) and fibrosis of the IFP may develop following knee joint surgery. Ultrasound enables visualization of IFP deformation (A1) from within the joint to the proximal area in response to muscle contraction, and this may be helpful in developing preventive and therapeutic strategies for IFP fibrosis.

View Article and Find Full Text PDF

Objective: In this study, we aimed to determine the effects of 2-week neuromuscular electrical stimulation (NMES) on quadriceps muscle atrophy and lower extremity motor score in individuals with subacute incomplete cervical spinal cord injury (SCI).

Methods: This stratified randomized controlled trial, conducted in the advanced critical care center of a university hospital, comprised 49 individuals with American Spinal Injury Association (ASIA) impairment scale grade C and D incomplete cervical SCI. The participants were stratified based on the ASIA impairment scale grade and randomly assigned to the control (n = 25) or NMES (n = 24) group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!