Elliptic flow (v(2)) values for identified particles at midrapidity in Au + Au collisions, measured by the STAR experiment in the beam energy scan at RHIC at sqrt[s(NN)] = 7.7-62.4 GeV, are presented. A beam-energy-dependent difference of the values of v(2) between particles and corresponding antiparticles was observed. The difference increases with decreasing beam energy and is larger for baryons compared to mesons. This implies that, at lower energies, particles and antiparticles are not consistent with the universal number-of-constituent-quark scaling of v(2) that was observed at sqrt[s(NN)] = 200 GeV.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.110.142301DOI Listing

Publication Analysis

Top Keywords

elliptic flow
8
particles antiparticles
8
beam energy
8
observation energy-dependent
4
energy-dependent difference
4
difference elliptic
4
particles
4
flow particles
4
antiparticles relativistic
4
relativistic heavy
4

Similar Publications

This study emphasizes the importance of optimizing pin-finned heat sinks as a means of addressing thermal engineering issues. It aims to investigate the use of perforations and unique fin designs in relation to staggered pin arrays in order to fill a gap in existing research. Three-dimensional incompressible flow simulation is performed with the Fluent software.

View Article and Find Full Text PDF

Influence of Geometric Parameters on The Hemodynamic Characteristics of The Vertebral Artery.

J Biomech Eng

January 2025

State Key Laboratory of Clean Energy Utilization, Zhejiang University, Yuquan Campus, 38 Zheda Road, Hangzhou 310027, Zhejiang, China; Shanghai Institute for Advanced Study of Zhejiang University, Zhangjiang Guochuang Center phase, No.799, Dangui Road, Shanghai 200120, China.

The carotid and vertebral arteries are principal conduits for cerebral blood supply and are common sites for atherosclerotic plaque formation. To date, there has been extensive clinical and hemodynamic reporting on carotid arteries; however, studies focusing on the hemodynamic characteristics of the vertebral artery (VA) are notably scarce. This article presents a systematic analysis of the impact of VA diameter and the angle of divergence from the subclavian artery (SA) on hemodynamic properties, facilitated by the construction of an idealized VA geometric model.

View Article and Find Full Text PDF

This paper introduces a Coriolis mass flow and density sensor. The sensor is made using Surface Channel Technology (SCT) but with selective wet etching to create the channels. This method forms suspended microfluidic channels with a larger cross-sectional area.

View Article and Find Full Text PDF

In response to the ongoing quest for more efficient renewable energy sources, this research addresses a significant gap in understanding the performance variations of Solar Chimney Power Plant (SCPP) models, particularly focusing on the influence of flow parameters in full and half-inclined collector sections featuring semi-elliptical curvature. The motivation stems from the need to optimize SCPP designs for enhanced energy generation while minimizing resource utilization and environmental impact. This research focuses on investigating flow parameter variations in Solar Chimney Power Plant (SCPP) models with full and half-inclined collector sections featuring semi-elliptical curvature and variable semi-minor heights (b: 0.

View Article and Find Full Text PDF

Investigating magnetic blood flow characteristics through arteries and micron-size channels for clinical therapies in biomedicine is becoming increasingly important with the rise of point-of-care diagnostics devices. A computational fluid dynamics (CFD) investigation is conducted to explore blood flow within a coronary artery affected by an elliptical stenosis near the artery wall under the influence of a magnetic field. The novelty of our study is the integration of Navier-Stokes and Maxwell's equations to calculate body forces on fluid flow, coupled with the application of magnetic fields both longitudinally and vertically, and the use of the Carreau-Yasuda model to analyse non-Newtonian blood rheology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!