An optical electrode design is presented that theoretically allows 100% optical transmission through an interdigitated metallic electrode at 50% metal areal coverage. This is achieved by redirection of light incident on embedded metal electrode lines to an angle beyond that required for total internal reflection. Full-field electromagnetic simulations using realistic material parameters demonstrate 84% frequency-averaged transmission for unpolarized illumination across the entire visible spectral range using a silver interdigitated electrode at 50% areal coverage. The redirection is achieved through specular reflection, making it nonresonant and arbitrarily broadband, provided the electrode width exceeds the optical wavelength. These findings could significantly improve the performance of photovoltaic devices and optical detectors that require high-conductivity top contacts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.39.005114 | DOI Listing |
J Environ Manage
January 2025
School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Key Laboratory of Environmental Engineering, Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China.
A self-driven electrochemical system (SDES) was utilized to treat anaerobic digestate wastewater, aiming to achieve wastewater resource utilization and energy generation. The efficiencies of pollutant removal, resource recovery, and energy production were enhanced by adjusting device parameters (anode area, external resistance, and electrode spacing). The high pollutant removal rates and struvite purity were achieved with the magnesium anode area of 15 cm, external resistance of 10 Ω, and electrode spacing of 10 cm.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
January 2025
Department of Radiology, Istanbul Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Purpose: Cochlear implantation (CI) surgery is essential for restoring hearing in individuals with severe sensorineural hearing loss. Accurate placement of the electrode within the cochlea is essential for successful auditory outcomes and minimizing complications. This study aims to analyze the relationship between the round window niche (RWN) alignment, its visibility during surgery, and the impact on surgical techniques and outcomes.
View Article and Find Full Text PDFJ Electromyogr Kinesiol
December 2024
Department of Biomedical Sciences for Health, Università degli Studi di Milano, via G. Colombo 71, 20133 Milan, Italy.
This study investigated the intra-day and inter-day reliability of electrical impedance myography (EIM) components and explored sex and regional differences in healthy adults' anterior thigh muscles. Using a multifrequency device, impedance values across various frequencies, alongside 50-kHz resistance (R), reactance (Xc), and phase angle (PhA) were assessed in both sexes and at whole anterior thigh, proximal and distal regions. Findings revealed excellent reliability (ICC > 0.
View Article and Find Full Text PDFJ Neurosurg
January 2025
1Department of Neurosurgery, Inselspital, Bern University Hospital, University Bern, Switzerland.
Objective: The effectiveness and optimal stimulation site of deep brain stimulation (DBS) for central poststroke pain (CPSP) remain elusive. The objective of this retrospective international multicenter study was to assess clinical as well as neuroimaging-based predictors of long-term outcomes after DBS for CPSP.
Methods: The authors analyzed patient-based clinical and neuroimaging data of previously published and unpublished cohorts from 6 international DBS centers.
ACS Appl Mater Interfaces
January 2025
State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!