Cryoablation is a surgical procedure used to freeze defective cells by inserting a low temperature probe into a human body to destroy malignant tissues. Miniaturized Joule-Thomson (J-T) refrigerators are often used to minimize the volume of the cooling device and reduce the destruction zone of normal tissue. The cooling effects of the existing probes are not uniformly generated along the longitudinal direction of the probe, which makes their applications less effective in surgeries of incompetent great saphenous veins (GSVs), where the target cells are distributed over a broad range. Long uniform refrigeration is required across the entire area of the probe to apply the same cooling effects. In this paper, a closed-loop J-T cryoablation probe was designed and fabricated to provide uniform refrigeration over a large area, with multiple expansion parts. Using flow boiling heat transfer, uniform cooling of a 200 mm-long and 0.3 mm thickness piece of target tissue was possible and simulated in a gelatin solution. The developed probe produced a greater than 53 K min(-1) cooling rate and the cooling temperature was below 253 K to satisfy the required cell death conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2014.07.017 | DOI Listing |
Res Sq
December 2024
Department of Electrical and Computer Engineering, Rice University, 6100 Main St, Houston, TX, 77005.
Wireless communication technologies for bioelectronic implants enable remote monitoring for diagnosis and adaptive therapeutic intervention without the constraints of wired connections. However, wireless data uplink from millimeter-scale devices deep in the body struggles to achieve low power consumption while maintaining large misalignment tolerances. Here, we report a passive wireless backscatter communication system based on magnetoelectric transducers that consumes less than 0.
View Article and Find Full Text PDFRes Sq
September 2024
Department of Electrical and Computer Engineering, Rice University, Houston, TX, USA.
ESC Heart Fail
February 2020
Section of Cardiology, San Francisco Veterans Affairs Medical Center and School of Medicine, University of California, San Francisco, CA, USA.
Aims: Clinical studies of vagal nerve stimulation (VNS) for heart failure with reduced ejection fraction have had mixed results to date. We sought to compare VNS delivery and associated changes in symptoms and function in autonomic regulation therapy via left or right cervical vagus nerve stimulation in patients with chronic heart failure (ANTHEM-HF), increase of vagal tone in heart failure (INOVATE-HF), and neural cardiac therapy for heart failure (NECTAR-HF) for hypothesis generation.
Methods And Results: Descriptive statistics were used to analyse data from the public domain for differences in proportions using Pearson's chi-square test, differences in mean values using Student's unpaired t-test, and differences in changes of mean values using two-sample t-tests.
Med Eng Phys
November 2014
Department of Radiology, Konkuk University Medical Center, Konkuk University School of Medicine 120-1 Neungdong-ro, Hwayang-Dong, Gangjin-gu, Seoul, South Korea.
Cryoablation is a surgical procedure used to freeze defective cells by inserting a low temperature probe into a human body to destroy malignant tissues. Miniaturized Joule-Thomson (J-T) refrigerators are often used to minimize the volume of the cooling device and reduce the destruction zone of normal tissue. The cooling effects of the existing probes are not uniformly generated along the longitudinal direction of the probe, which makes their applications less effective in surgeries of incompetent great saphenous veins (GSVs), where the target cells are distributed over a broad range.
View Article and Find Full Text PDFJ Am Assoc Gynecol Laparosc
May 2000
3931 Sorrento Valley Boulevard, San Diego, CA 92121, USA.
A new cryosurgical device was developed in an attempt to overcome problems of current systems. It incorporates a mixed-fluid J-T stage, thereby reducing working pressure. This allows incorporation of an oil-free compressor to circulate the mixture and eliminates the need for coolant replenishment.