Finite helical axes (FHAs) are a potentially effective tool for joint kinematic analysis. Unfortunately, no straightforward guidelines exist for calculating accurate FHAs using prepackaged six degree-of-freedom (6 DOF) rigid body trackers. Thus, this study aimed to: (1) describe a protocol for calculating FHA parameters from 6 DOF rigid body trackers using the screw matrix and (2) to maximize the number of accurate FHAs generated from a given data set using a moving window analysis. Four Optotrak® Smart Markers were used as the rigid body trackers, two moving and two fixed, at different distances from the hinge joint of a custom-machined jig. 6D OF pose information was generated from 51 static positions of the jig rotated and fixed in 0.5 deg increments up to 25 deg. Output metrics included the FHA direction cosines, the rotation about the FHA, the translation along the axis, and the intercept of the FHA with the plane normal to the jig's hinge joint. FHA metrics were calculated using the relative tracker rotation from the starting position, and using a moving window analysis to define a minimum acceptable rotational displacement between the moving tracker data points. Data analysis found all FHA rotations calculated from the starting position were within 0.15 deg of the prescribed jig rotation. FHA intercepts were most stable when determined using trackers closest to the hinge axis. Increasing the moving window size improved the FHA direction cosines and center of rotation accuracy. Window sizes larger than 2 deg had an intercept deviation of less than 1 mm. Furthermore, compared to the 0 deg window size, the 2 deg window had a 90% improvement in FHA intercept precision while generating almost an equivalent number of FHA axes. This work identified a solution to improve FHA calculations for biomechanical researchers looking to describe changes in 3D joint motion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.4028413 | DOI Listing |
Math Biosci
December 2024
School of Mathematics and Statistics, University of Melbourne, Melbourne, Australia. Electronic address:
A model using the rigid body multi-cellular framework (RBMCF) is implemented to investigate the mechanisms of buckling of an epithelial monolayer. Specifically, the deformation of a monolayer of epithelial cells which are attached to a basement membrane and the surrounding stromal tissue. The epithelial monolayer , supporting basement membrane and stromal tissue are modelled using two separate vertex dynamics models (one for the epithelial monolayer layer and one for the basement membrane and stromal tissue combined) and interactions between the two are considered using the RBMCF to ensure biologically realistic interactions.
View Article and Find Full Text PDFSci Rep
December 2024
Liaoning Institute of Technology and Equipment for Mineral Resources Development and Utilisation in Higher Educational Institutions, Liaoning Technical University, Fuxin, 123000, Liaoning, China.
Water is one of the most important influences on slope stability in open pit mines. In order to solve the problem of slope stability analysis in multi-aquifer open pit mines, the open pit mine in Block I of Thar Coalfield in Pakistan with multiple aquifers was taken as the research background. The groundwater flow field at different excavation phases was analyzed by numerical simulation method.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
College of Mechanical and Electrical Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China.
The body structures and motion stability of worm-like and snake-like robots have garnered significant research interest. Recently, innovative serial-parallel hybrid segmented robots have emerged as a fundamental platform for a wide range of motion modes. To address the hyper-redundancy characteristics of these hybrid structures, we propose a novel caterpillar-inspired Stable Segment Update (SSU) gait generation approach, establishing a unified framework for multi-segment robot gait generation.
View Article and Find Full Text PDFClin Spine Surg
October 2024
Department of Orthopaedics, NYU Langone Orthopedic Hospital, New York, NY.
Study Design: Single-center retrospective cohort study.
Objective: To compare the correction of fractional curve and L5 tilt in 2RVBT versus PSF with LIV in the lumbar spine.
Summary Of Background Data: Vertebral body tethering, an AIS fusion-alternative, avoids rigid constructs, allowing for lower instrumented vertebra (LIV) selection.
Adv Healthc Mater
December 2024
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA.
Both rigid plastics and soft hydrogels find ample applications in engineering and medicine but bear their own disadvantages that limit their broader applications. Bonding these mechanically dissimilar materials may resolve these limitations, preserve their advantages, and offer new opportunities as biointerfaces. Here, a robust adhesion strategy is proposed to integrate highly entangled tough hydrogels and diverse plastics with high interfacial adhesion energy and strength.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!