Purpose: Proper occlusal contact is important for the long-term success of prosthodontic therapy. We clarified the effects of occlusal loading force on occlusal contact in natural dentition by comparing measured values for occlusal loading and occlusal contact area.
Methods: Masseter muscle activity was measured in 10 subjects (2 male, 8 female; mean age, 27 years) with natural dentition using electromyography, with clenching at full strength with nothing interposed between the upper and lower teeth defined as 100% maximum voluntary contraction (MVC). Pressure-sensitive film (Occluzer) was used to examine occlusal contact points at 20, 40, 60, 80, 100 and 120% MVC. A material for checking accuracy of fit (BiteEye) was used to examine occlusal contact points at 20, 40, 60 and 80% MVC. ANOVA and the Bonferroni method were used to assess the results, with the level of significance set at 5%. Coefficients of variation (CV) were also calculated by dividing the standard deviation by the mean.
Results: Occlusal loading and occlusal contact area increased with clenching strength; however, CV showed differences between the methods at low and high MVC.
Conclusions: With Occluzer, testing should be carried out at clenching strength ≥ 60% MVC. With BiteEye, testing should be carried out from light clenching strength at 20% MVC to moderate clenching strengths at 40-60% MVC. Occluzer and BiteEye (10 μm) gave similar occlusal contact areas at 60-80% MVC. These results suggest that combined use of Occluzer and BiteEye gives an accurate picture of occlusion from weak to strong clenching strength.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpor.2014.07.001 | DOI Listing |
J Clin Med
January 2025
Department of Reconstructive Dentistry, UZB University Center for Dental Medicine Basel, University of Basel, 4058 Basel, Switzerland.
The technical development of implant-supported fixed dental prostheses (iFDP) initially concentrated on the computer-aided manufacturing of prosthetic restorations (CAM). Advances in information technologies have shifted the focus for optimizing digital workflows to AI-based processes for design (CAD). This pre-clinical pilot trial investigated the feasibility of the automatic design of three-unit iFDPs using CAD software (Dental Manger 2021, 3Shape; DentalCAD 3.
View Article and Find Full Text PDFJ Contemp Dent Pract
September 2024
Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.
Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.
Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.
Orthod Craniofac Res
January 2025
Department of Orthodontics, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, China.
Background: Different protocols exist regarding wear time of invisible aligners. There is no study that compared the effect of different protocols. The aim of this study was to assess the effect of Invisalign aligners in four first-premolar extraction treatments in adolescents using three aligner wear protocols, every 7, 10 and 14 days.
View Article and Find Full Text PDFJ Indian Prosthodont Soc
January 2025
Department of Prosthodontics, Sri Ramachandra Dental College and Hospital, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India.
Aim: Aberrative occlusal contacts were associated with Temporomandibular disorder (TMD), but whether stabilization splints with therapeutic exercises alleviate the symptoms is unclear. Hence, this study aims to compare the short-term efficacy of occlusal splint therapy and the synergistic effect of therapeutic exercise with occlusal splint therapy for 3 weeks in individuals with TMD.
Settings And Design: in-vivo observational pilot study.
Dent J (Basel)
November 2024
Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, MA 02115, USA.
Occlusion plays a crucial role in the long-term success and functionality of dental restorations. The purpose of this study was to investigate the changes in occlusal contacts upon the cementation of zirconia crowns with different cement spacer settings in computer-aided design and computer-aided manufacturing (CAD-CAM) software (3Shape Dental System version 2.102.