Evaluation of the NucliSens EasyQ v2.0 assay in comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in quantification of C-clade HIV-1 in plasma.

PLoS One

Department of Paediatrics, University of Oxford, Oxford, Oxfordshire, United Kingdom; HIV Pathogenesis Programme, University of KwaZulu-Natal, Durban, KwaZulu-Natal, South Africa; The Ragon Institute of Massachusetts General Hospital, Massachusetts Institute of Technology and Harvard University, Boston, Massachusetts, United States of America.

Published: May 2015

Human immunodeficiency virus type 1 (HIV-1) genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART)-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test version 2.0 by Roche (CAP/CTM v2.0), the BioMérieux NucliSens Version 2.0 Easy Q/Easy Mag (NucliSens v2.0) and the Roche COBAS Amplicor HIV-1 Monitor Test Version 1.5 (Amplicor v1.5). Strong linear correlation was observed and Bland-Altman analyses showed overall good agreement between the assays with mean viral load differences of 0.078 log cp/ml (NucliSens v2.0 - Amplicor v1.5), 0.260 log cp/ml (CAP/CTM v2.0 - Amplicor v1.5) and 0.164 log cp/ml (CAP/CTM v2.0 - NucliSens v2.0), indicating lower mean viral load results for the Amplicor v1.5 and higher mean readings for the CAP/CTM v2.0. Consistent with observations following previous comparisons of CAP/CTM v2.0 versus Amplicor v1.5, the CAP/CTM v2.0 assay detected low-level viremia (median 65 cp/ml) in more than one-third of those in whom viremia had been undetectable (<20 cp/ml) in assays using the NucliSens platform. These levels of viremia are of uncertain clinical significance but may be of importance in early detection of ART resistance in those on treatment. Overall the three assays showed good comparability of results but with consistent, albeit relatively small, discrepancies for HIV-1 clade-C samples, especially in the low-viremic range that should be taken into account when interpreting viral load data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4144839PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0103983PLOS

Publication Analysis

Top Keywords

amplicor v15
24
cap/ctm v20
24
viral load
12
nuclisens v20
12
log cp/ml
12
v20
11
v20 assay
8
roche cap/ctm
8
hiv-1 test
8
test version
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!