A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of respiratory point compensation in healthy adults: Can non-invasive near-infrared spectroscopy help? | LitMetric

Objectives: We tested the hypothesis that the respiratory compensation point can be accurately determined in healthy participants during incremental cycling exercise using non-invasive near-infrared spectroscopy-derived measures of deoxygenated hemoglobin (deoxyHb).

Design: Validation study.

Methods: 118 healthy men (average age 47 ± 19 yrs, range 20-79 yrs) performed an incremental cycling test to exhaustion. Breath-by-breath pulmonary oxygen uptake (VO2) and other ventilatory and gas exchange variables were measured and used to determine respiratory compensation point. Vastus lateralis deoxyHb was monitored using a frequency domain multi-distance system near-infrared spectroscopy device and deoxyHb data were modeled with a piece-wise double-linear function from which the deoxyHb deflection point (deoxyHbDP) was determined. The absolute (L min(-1)) and relative (% maximal VO2 [VO 2max]) VO2 values associated with the respiratory compensation point and deoxyHbDP were determined for each individual.

Results: DeoxyHb increased as a function of exercise intensity up to a point (deoxyHbDP) after which the signal displayed a "near-plateau". The deoxyHbDP corresponded to a VO2 of 2.25 ± 0.69 L min(-1) (74 ± 12% VO 2max) which was not significantly different from the VO2 at respiratory compensation point (2.28 ± 0.70 L min(-1) and 74 ± 10% VO 2max, p < 0.05). Both indices were highly correlated (r(2) = 0.86) and Bland Altman analyses confirmed a non-significant bias for VO2 (-0.024 L min(-1)) concomitant with a small imprecision of 0.26 L min(-1).

Conclusions: During incremental cycling exercise, the VO2 associated with the onset of a plateau in near-infrared spectroscopy-derived deoxyHb occurs in coincidence with the VO2 at respiratory compensation point suggesting that respiratory compensation point can be accurately estimated, non-invasively, using near-infrared spectroscopy-derived deoxyHb in alternative to the use of ventilatory-based techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jsams.2014.07.016DOI Listing

Publication Analysis

Top Keywords

respiratory compensation
24
compensation point
24
incremental cycling
12
near-infrared spectroscopy-derived
12
point deoxyhbdp
12
point
9
non-invasive near-infrared
8
near-infrared spectroscopy
8
point accurately
8
cycling exercise
8